A Preliminary Study of MRI with Zero Echo Time Sequence for Combined Fracture and Rotator Cuff Assessment in Proximal Humerus Fractures.
Mehmet Kaymakoglu, Ulas Can Kolac, Burak Dalkıran, Ahmet Gurkan Erdemir, Adalet Elcin Yildiz, Gokhan Ayik, Üstün Aydıngöz, Gazi Huri
Izmir University of Economics, Faculty of Medicine, Department of Orthopedics and Traumatology, Izmir, Turkey. Electronic address: kaymakoglumehmet@gmail.com. · Hacettepe University Faculty of Medicine, Department of Orthopedics and Traumatology, Ankara, Turkey.
Key points
From the paper's conclusion- ZTE MRI provides fracture assessment comparable to CT, with similar intra- and interobserver reliability across major fracture components. Beyond matching CT performance in PHF characterization, ZTE MRI offers the significant advantages of radiation-free imaging and simultaneous assessment of full-thickness rotator cuff tears using conventional MRI sequences. These preliminary findings suggest that ZTE MRI may serve as a reliable alternative to CT in the initial evaluation of PHF, particularly when a comprehensive assessment of both bone and soft tissue is desired. Larger prospective studies are needed to validate the clinical impact of these observations.
Abstract
BACKGROUND: Proximal humerus fractures (PHF) are common in the elderly population, and accurate fracture characterization is essential for treatment planning. Computed tomography (CT) improves fracture visualization; however, radiation exposure and shortcomings in soft-tissue evaluation are its main disadvantages. Magnetic resonance imaging with ZTE sequence (ZTE MRI) enables CT-like imaging and enhances bone imaging while simultaneously allowing for the evaluation of soft tissues using standard sequences, all without radiation exposure. We hypothesized that ZTE MRI would demonstrate diagnostic performance comparable to CT in the classification of PHF, while also offering the added value of soft-tissue assessment. METHODS: This retrospective comparative study included patients with PHF who underwent shoulder MRI with a ZTE sequence within 21 days after CT. Two independent observers (orthopedic surgeon, radiologist) evaluated anonymized CT and ZTE MRI datasets in separate sessions for Neer fracture type, articular extensions, fracture dislocations and glenoid fractures with a two-week period between modalities. Standard MRI sequences were reviewed to identify concomitant rotator cuff and long head of biceps tendon injuries. Intra- and interobserver agreement was assessed using Cohen's kappa and intraclass correlation coefficients. RESULTS: Thirty-six patients met the inclusion criteria. ZTE MRI demonstrated very good agreement with CT for Neer classification (κ = 0.840, p < 0.001). Interobserver agreement ranged from 0.52-0.80 on CT and 0.46-0.72 on ZTE MRI. Intraobserver agreement was high for both observers, ranging 0.70-0.90 on CT and 0.68-0.88 on ZTE MRI. The highest reproducibility was observed for the humeral head, greater tubercle, and surgical neck fracture components. Conventional MRI sequences identified full-thickness rotator cuff tears in 12 of 36 patients (33.3%), including patients with minimally displaced fractures. CONCLUSION: ZTE MRI provides fracture assessment comparable to CT, with similar intra- and interobserver reliability across major fracture components. Beyond matching CT performance in PHF characterization, ZTE MRI offers the significant advantages of radiation-free imaging and simultaneous assessment of full-thickness rotator cuff tears using conventional MRI sequences. These preliminary findings suggest that ZTE MRI may serve as a reliable alternative to CT in the initial evaluation of PHF, particularly when a comprehensive assessment of both bone and soft tissue is desired. Larger prospective studies are needed to validate the clinical impact of these observations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Evaluation of Cervical Spine Morphometry: Zero Echo Time MRI Versus Multislice CT.Journal of magnetic resonance imaging : JMRI · 2026
- Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study.Diagnostics (Basel, Switzerland) · 2026
- Diagnostic performance of zero-echo time (ZTE) MRI for preoperative evaluation of cervical OPLL complicated with dural ossification (DO): a retrospective study.Skeletal radiology · 2026
- Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols.Diagnostics (Basel, Switzerland) · 2026
- Zero echo time versus T1-weighted gradient-recalled echo MRI of breast biopsy markers: a phantom study comparing susceptibility artifact volume and geometric dimensions.Translational breast cancer research : a journal focusing on translational research in breast cancer · 2026
- Anterior Infraspinatus Tendon Lesions and Selective Superior Muscle Belly Atrophy: A Case Series Introducing a Novel Ultrasound-Based Approach for Precise Rotator Cuff Tear Localization.Pain and therapy · 2026