Diagnostic performance of zero-echo time (ZTE) MRI for preoperative evaluation of cervical OPLL complicated with dural ossification (DO): a retrospective study.
Baiyang Jiang, Qianxi Jin, Dongqing Zhu, Xin Zhang, Weijin Zhang, Jiayi Zhang, Guangwen Duan, Meiling Xu,
Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, 200003, China. · Department of Orthopedic Surgery, Second Affiliated Hospital of Naval Medical University, Shanghai, 200003, China.
Key points
From the paper's conclusion- ZTE-MR imaging offers a nonionizing, highly sensitive, and reproducible approach for diagnosing cervical OPLL with DO and serves as a valuable adjunct to conventional sequences for preoperative evaluation.
Abstract
OBJECTIVE: To evaluate the diagnostic efficacy of zero-echo time (ZTE) magnetic resonance imaging (MRI) for cervical ossification of the posterior longitudinal ligament (OPLL) complicated by dural ossification (DO), compared with T1-weighted imaging (T1WI) and T2-weighted imaging (T2WI). MATERIALS AND METHODS: This retrospective single-center study included 73 consecutive OPLL patients (52 males, 21 females; mean age 55.5 ± 10.6 years) admitted between April 2025 and October 2025. All underwent 1-mm thin-slice computed tomography (CT) (gold standard) and 3.0T MRI (T1WI, T2WI, and ZTE). Two senior radiologists blindly assessed DO presence. Sensitivity, specificity, diagnostic accuracy, area under the curve (AUC), and Cohen's κ interobserver agreement coefficient were calculated, with McNemar's and DeLong's tests applied for interreader and pairwise AUC statistical comparisons, respectively. RESULTS: CT confirmed 46 cases (63.0%) of cervical OPLL complicated with DO. For the ZTE sequence, the diagnostic sensitivity of the two readers was 93.5% and 95.7%, specificity was 96.3% and 88.9%, accuracy was 94.5% and 93.2%, and AUC was 0.949 and 0.923, respectively. These metrics were significantly superior to those of T1WI imaging (AUC 0.522-0.536) and T2WI imaging (AUC 0.550-0.572). DeLong's test confirmed that the AUC of ZTE was significantly higher than that of T1WI (P < 0.001) and T2WI (p < 0.001), while there was no significant difference between T1WI and T2WI (p > 0.05). Regarding interobserver consistency: the Cohen's κ value for ZTE was 0.854, while those for T1WI and T2WI were -0.043 and 0.466, respectively. CONCLUSION: ZTE-MR imaging offers a nonionizing, highly sensitive, and reproducible approach for diagnosing cervical OPLL with DO and serves as a valuable adjunct to conventional sequences for preoperative evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incremental Diagnostic Value of Zero-Echo-Time Magnetic Resonance Imaging for Osseous Cervical Neural Foraminal Stenosis: A Retrospective Multireader Study.Diagnostics (Basel, Switzerland) · 2026
- Quantitative Evaluation of Cervical Spine Morphometry: Zero Echo Time MRI Versus Multislice CT.Journal of magnetic resonance imaging : JMRI · 2026
- Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols.Diagnostics (Basel, Switzerland) · 2026
- A Preliminary Study of MRI with Zero Echo Time Sequence for Combined Fracture and Rotator Cuff Assessment in Proximal Humerus Fractures.Journal of shoulder and elbow surgery · 2026
- Zero echo time versus T1-weighted gradient-recalled echo MRI of breast biopsy markers: a phantom study comparing susceptibility artifact volume and geometric dimensions.Translational breast cancer research : a journal focusing on translational research in breast cancer · 2026
- Pars defect detection with 3 T GE ZeroTE bone MRI in children, adolescents and young adults with low back pain: a pilot study of inter-rater reproducibility and CT-linked feasibility.Skeletal radiology · 2026