Diagnostics (Basel, Switzerland)

Transthoracic Echocardiography-Assisted, Low-Fluoroscopy Left Bundle Branch Area Pacing: A Comparison of Implantation Approaches and Lead Types.

Po-Hua Chu, Chung-Lieh Hung, Kuo-Tzu Sung, Shu-Fen Hsu, Cheng-Ting Tsai, Jen-Yuan Kuo, Sheng-Hsiung Chang

Cardiovascular Division, Department of Internal Medicine, MacKay Memorial Hospital, Taipei 104217, Taiwan. · Department of Telehealth, MacKay Memorial Hospital, Taipei 104217, Taiwan.

Observational · n=45

Key points

From the paper's conclusion
  • However, the SDL group exhibited significantly higher pacing thresholds at implant and 6 months (p < 0.05) and maintained a higher numerical trend through Year 4, though both lead types demonstrated stable chronic sensing and impedance profiles.

Abstract

Background: Transthoracic echocardiography (TTE)-assisted left bundle branch area pacing (LBBAP) is a potential supplementary to fluoroscopy-guided implantation and may reduce radiation. Objectives: To evaluate the feasibility and long-term stability of TTE-assisted, low-fluoroscopy LBBAP across different workflows and lead types. Methods: This retrospective study enrolled 45 consecutive patients between November 2021 and June 2022, analyzing 42 successful cases. Patients were stratified by workflow approach (non-scrubbed, n = 24; scrubbed aseptic, n = 18) and lead type (lumen-less leads [LLLs], n = 20; stylet-driven leads [SDLs], n = 22). Procedural and pacing parameters were assessed through a 4-year follow-up. Results: In select patients with adequate acoustic windows, multi-stage TTE-assisted LBBAP remained feasible despite a 54.8% overweight/obesity rate. The scrubbed aseptic workflow showed significantly shorter procedural and fluoroscopy times (p < 0.01), though confounded by the learning curve. Beyond 6 months, pacing parameters remained stable and comparable between workflows through 4 years. Regarding lead types, procedural durations were similar. However, the SDL group exhibited significantly higher pacing thresholds at implant and 6 months (p < 0.05) and maintained a higher numerical trend through Year 4, though both lead types demonstrated stable chronic sensing and impedance profiles. No late dislodgements, device-related infections, or late complications occurred across available patient-years. Conclusions: TTE-assisted LBBAP is a clinically feasible approach that can supplement conventional implantation in selected patients with favorable acoustic windows. While achieving excellent 4-year functional durability, procedural improvements reflect the combined effect of workflow refinement and operator proficiency.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Transthoracic Echocardiography-Assisted, Low-Fluoroscopy Left Bundle Branch Area Pacing: A Comparison of Implantation Approaches and Lead Types — Science Skim