Performance and safety of a fixed-helix stylet-driven lead for left bundle branch area pacing: a multicenter registry
A Abdin, D Amelingmeyer, H Almasri, F Buder, C Werner, S Lopez-Katern, T Kessler, P Luedike
Key points
From the paper's conclusion- Conclusion In this multicenter registry, the fixed-helix, stylet-driven FINELINE™ lead met all prespecified safety and performance goals for LBBAP.
Abstract
Background Stylet-driven leads (SDLs) may facilitate septal penetration during left bundle branch area pacing (LBBAP), but concerns remain regarding fixation stability and long-term performance. The FINELINE™ lead is the thinnest available SDL and features a fixed helix that advances synchronously with the lead body to enhance fixation. We aimed to evaluate handling characteristics, safety, and electrical performance of the FINELINE lead in patients undergoing LBBAP. Methods This multicenter registry included consecutive patients undergoing LBBAP using the FINELINE™ lead at two German centers. Data were collected retrospectively and prospectively. Prespecified safety and effectiveness performance goals were adopted from prior LBBAP registries: (1) lead-related complication (LRC)–free rate >90% at last follow-up; (2) pacing capture threshold (PCT) ≤2.0 V at 0.4 ms and R-wave amplitude ≥5 mV in ≥80% of patients. Outcomes were benchmarked against published results of the INGEVITY lead from the INSIGHT-LBBP registry. Results A total of 435 patients were included (mean age 77 ± 9 years, 37% female). Indications were atrioventricular block, bradycardia, pace-and-ablate strategies and heart failure. Median follow-up was 10 months The LRC-free rate was 97.0% (95% CI 95.0–98.4%), exceeding the prespecified safety performance goal of 90%. At 10 months, 99.5% of patients had PCT ≤2.0 V, and 94.7% had R-wave amplitudes ≥5 mV. Electrical parameters remained stable throughout follow-up. Observed outcomes were consistent with previously reported performance of the INGEVITY lead in LBBAP. Conclusion In this multicenter registry, the fixed-helix, stylet-driven FINELINE™ lead met all prespecified safety and performance goals for LBBAP. These findings support the use of thin SDL technology as a viable alternative for LBBAP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficacy and safety of left bundle branch area pacing performed with stylet-driven leads.Frontiers in cardiovascular medicine · 2026
- Procedural performance and safety of a helix locking tool for left bundle branch pacing: a prospective multicenter study.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- Relationship between site procedural volumes and outcomes of left bundle branch area pacing using stylet-driven leads from the INSIGHT-LBBA Registry.Heart rhythm O2 · 2026
- Fixation beat distribution across transseptal transitions during left bundle branch pacing: availability varies among patientsFrontiers in Cardiovascular Medicine · 2026
- Septal to lateral delay: a practical ECG-derived measure to determine left ventricular dyssynchrony in left bundle branch pacingEuropean Heart Journal · 2026
- Comparative clinical outcomes of stylet-driven left bundle branch area pacing versus right ventricular pacing in patients with preserved ejection fraction: A 3-year follow-up study.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026