Fluoroscopic target zone for left bundle branch area pacing (LBBAP) optimized for cardiac conduction system proximity: a computed tomography study
M Lis, J Garbacz, A Priadka, T Puto, R Banys, M Krupinski, N Duong, H Roukoz,
Key points
From the paper's conclusion- We identified the left bundle origin, His bundle, right ventricular (RV) apex, and tricuspid annulus and simulated pacing leads co-axially along the left bundle system, entering the septum 20 mm apical to the annulus.
Abstract
Background Optimizing Left bundle branch area pacing (LBBAP) outcomes depends on proximity of the pacing electrode to the cardiac conduction system, particularly the origin of the left bundle. However, current fluoroscopic LBBAP targeting recommendations use fixed distances from the His position and does not account for potential patient-specific septal anatomy variation. Purpose To develop a computed tomography–derived fluoroscopic targeting strategy for left bundle branch area pacing that maximizes conduction system proximity while avoiding damage to the tricuspid septal leaflet and aortic sinuses. Methods Coronary computed tomography angiography from 27 patients with structurally normal hearts (mean ejection fraction 70±10%) was used to build three-dimensional models (Fig. 1). We identified the left bundle origin, His bundle, right ventricular (RV) apex, and tricuspid annulus and simulated pacing leads co-axially along the left bundle system, entering the septum 20 mm apical to the annulus. In the right anterior oblique (RAO) 30° projection, the His–to–RV apex horizontal line defined a reference segment (0% His, 100% apex). Vertical position was measured perpendicular to it, with the His level as 0, and values above or below reported as ±, but presented as % of the length of the reference segment. For each target, we measured endocardial surface distance from the lead tip to the left bundle origin. Results At 20 mm from tricuspid annulus, all targets in RAO 30 clustered at approximately one third of the horizontal His–to–RV apex distance. Vertical position, separated the targets: the septal target lay close to the His level (-1.6±10.8%); superior above (+15.8±6.8%) inferior below (−32.4±18.7%). The septal fascicle target provided the best balance of feasibility and precision, with close proximity to the left bundle origin (19±5 mm), while the anterior trajectory was slightly closer but more cranial (14.0±3.0 mm) and was not feasible in 15.9% of models because it intersected the aortic sinus; the posterior trajectory was more distant (32.7±8.7 mm). Conclusion The septal fascicle region was identified as the most practical left bundle branch area pacing target when aiming for cardiac conduction system proximity. In RAO 30, this region is accessible at roughly one third of the His–to–RV apex distance and near the His level on the normalized vertical axis, providing an anatomy-informed reference for LBBAP–proximal lead deployment.Figure 1
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Step-By-Step Left Bundle Branch Area Pacing: A Practical Technical Guide.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- A Novel Method for Assessing Left Bundle Branch Capture Using the Bidirectional Conduction Time Difference Between Left Bundle Branch Area Pacing and Coronary Sinus Leads.Heart rhythm · 2026
- Effects of LBBAP Pacing-Site Position under a Modelled Proximal LBBB: A 24-Model Electrophysiological Simulation Study.Medical engineering & physics · 2026
- CTA-Guided Anatomical Targeting for Bachmann's Bundle Pacing: First-in-Human Study.Heart rhythm · 2026
- The flexibility of delayed fluoroscopic left ventricular angiography in periprocedural real-time visualization of the lead tip in left bundle branch pacing.Heart rhythm O2 · 2026
- Quantitative CT Lead Localization Reveals Proximal Left Bundle Targeting Facilitates Superior Physiologic Pacing.Heart rhythm · 2026