From Iodine Maps to Brain Window Images: Quantitative Visibility Thresholds of Iodine Staining Using Photon-Counting CT-A Retrospective Observational Study.
Marie-Christine Pali, Stephanie Mangesius, Constantin Emanuel Eisenschink, Philipp Deisl, Lukas Neumann, Michael Knoflach, Raimund Pechlaner, Bernhard Glodny,
Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria. · Department of Basic Sciences in Engineering Sciences, University of Innsbruck, 6020 Innsbruck, Austria.
Key points
From the paper's conclusion- Objectives: We aimed to determine quantitative photon-counting CT (PCCT)-derived iodine map (IM) attenuation associated with visual detectability of parenchymal hyperattenuation on conventional brain window (BW) images after mechanical thrombectomy (MT) and to assess corresponding relative BW attenuation changes.
Abstract
Objectives: We aimed to determine quantitative photon-counting CT (PCCT)-derived iodine map (IM) attenuation associated with visual detectability of parenchymal hyperattenuation on conventional brain window (BW) images after mechanical thrombectomy (MT) and to assess corresponding relative BW attenuation changes. Methods: In this retrospective single-center study, 12 patients with anterior circulation large vessel occlusion underwent MT followed by post-interventional PCCT. BW, IM, and virtual non-contrast reconstructions were generated. Follow-up non-contrast CT served as reference for final infarction extent. Of 54 ASPECTS regions with final infarction, 40 showed IM hyperattenuation and were included in the detectability analysis. Two blinded readers assessed visual detectability. IM attenuation and relative BW attenuation increase (%ΔHU) were evaluated using ROC analysis with clustered bootstrap resampling. Thresholds were determined using the Youden index. Results: Across all 54 regions with final infarction, median IM attenuation was significantly higher in infarcted than contralateral regions (6.39 vs. 2.18 HU, p < 0.001), while absolute BW attenuation did not differ significantly. Among the 40 regions with IM hyperattenuation, 15 were visually detectable on BW images. ROC analysis showed excellent performance for IM (AUC = 0.997) and %ΔHU (AUC = 0.984). The optimal IM threshold in the original cohort was 8.33 HU (sensitivity 100%, specificity 96.0%), and the optimal %ΔHU threshold was 3.06% (sensitivity 100%, specificity 92.0%). Bootstrap-derived median thresholds were 11.69 HU (95% interval 8.33-12.67) for IM and 3.06% (3.06-20.16%) for %ΔHU. Inter-reader agreement was excellent (κ = 0.81-0.86). Conclusions: PCCT-derived iodine quantification enables objective assessment of visual detectability of post-interventional parenchymal hyperattenuation. In this cohort, an internally derived IM cutoff of 8.33 HU was associated with BW visibility. These preliminary findings require validation in larger, independent multicenter cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Image quality and artefact reduction for tantalum clips in ocular proton therapy using photon-counting CT.European radiology experimental · 2026
- Spectral ultrahigh-resolution photon-counting CT for coronary stent imaging: evaluation in a dynamic phantomEuropean Radiology Experimental · 2025
- Photon-counting-CT – der neue Standard in der kardiovaskulären Diagnostik?Wiener klinisches Magazin · 2026
- Virtual Noncontrast Imaging with Deep-Silicon Photon-Counting CT: Matched Phantom and Initial Human EvaluationmedRxiv · 2026
- Evaluation of iodine detection and quantification limits in photon-counting CT-a phantom study.European radiology experimental · 2026
- PET Attenuation Map Generation for Brain Imaging from Virtual Non-Contrast and Virtual Non-Iodine Images Obtained with Photon Counting CT ScannersarXiv · 2026