Image quality and artefact reduction for tantalum clips in ocular proton therapy using photon-counting CT.
Lea Esser, Christian Bäumer, Benedikt M Schaarschmidt, Dominik Lisowski, Hannah Steinberg-Vorhoff, Michal-Kamil Chodyla, Aleksandar Milosevic, Beate Timmermann,
West German Proton Therapy Centre Essen (WPE), Essen, Germany. Lea.Esser@sjk.uk-essen.de. · West German Proton Therapy Centre Essen (WPE), Essen, Germany.
Key points
From the paper's conclusion- Relevance statement Photon-counting CT combined with iterative metal artefact reduction can improve visualisation of tantalum clips and surrounding anatomy in ocular proton therapy planning and may support more reliable tumour localisation despite limited objective differences compared with state-of-the-art conventional CT.
Abstract
OBJECTIVE: Tantalum fiducials ("clips") used in intraocular proton therapy generate strong artefacts in conventional computed tomography, limiting the visibility of tumours and anatomical structures. This study investigated the potential of photon-counting computed tomography (PCCT) for reducing tantalum-related artefacts. MATERIALS AND METHODS: Two phantom models containing tantalum clips were examined using a photon-counting CT system and two conventional CT scanners with energy-integrating detectors (EICT). Reconstruction parameters, including tube voltage, image resolution, reconstruction kernel, virtual monoenergetic imaging (VMI), and iterative metal artefact reduction (iMAR), were systematically optimised. Image quality was evaluated using objective metrics assessing homogeneity, noise, contrast, structural similarity, and artefact volume, complemented by a blinded subjective observer study. Correlations between objective and subjective results were analysed using Spearman's rank correlation. RESULTS: Objectively, PCCT showed no significant advantage over the modern EICT scanner but significantly outperformed the older-generation EICT therapy simulator. In contrast, blinded observers consistently preferred PCCT images. iMAR was the dominant factor influencing image quality. VMI alone did not yield relevant improvements. High-energy VMI (110 keV) combined with iMAR achieved the best subjective ratings. Higher spatial resolution due to smaller voxel sizes showed no clinically relevant benefit for artefact reduction. Soft reconstruction kernels provided the best balance between artefact suppression and image noise. Objective rankings correlated strongly with subjective assessments. CONCLUSION: PCCT combined with iMAR improves subjective image quality in intraocular proton therapy and reduces the perceived severity of tantalum artefacts. Nevertheless, tantalum remains a major challenge in image-guided proton therapy, requiring further optimisation of imaging and reconstruction strategies. KEY POINTS: Question Photon-counting CT may improve visualisation of tantalum clips and reduce metal artefacts in ocular proton therapy planning compared with conventional CT systems. Findings Photon-counting CT achieved the highest subjective image quality ratings, while iterative metal artefact reduction remained the dominant factor influencing artefact suppression. Relevance statement Photon-counting CT combined with iterative metal artefact reduction can improve visualisation of tantalum clips and surrounding anatomy in ocular proton therapy planning and may support more reliable tumour localisation despite limited objective differences compared with state-of-the-art conventional CT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Understanding Photon-Counting CT: Physics, Detector Technology, and Image Reconstructions.Sensors (Basel, Switzerland) · 2026
- Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.European journal of radiology · 2026
- Photon-Counting Detector CT for Imaging Around Orthopedic and Spinal Metallic Implants: A Systematic Review.Cureus · 2026
- Photon-Counting Computed Tomography in the Era of Precision Medicine: Technological Advances, Artificial Intelligence Integration, and Multidisciplinary Clinical ApplicationsInternational Science Journal · 2026
- Photon-counting CT in tumor imaging: A review of comparative evaluations and technical innovations.Journal of X-ray science and technology · 2026
- Optimizing photon counting detector CT reconstructions for automatic vessel tracing in prostate artery embolization.Journal of applied clinical medical physics · 2026