Comparative Analysis of Four Commercially Available Artificial Intelligence Software for Brain Volumetry.
Gaspare Saltarelli, Giovanni Di Cerbo, Antonio Innocenzi, Marco De Chellis, Federico Bruno, Alessandra Splendiani, Ernesto Di Cesare
Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, 67100 L'Aquila, Italy.
Key points
From the paper's conclusion- Agreement was structure-dependent: excellent for lateral ventricles (single-measure ICC ≈ 0.92 [0.85-0.96]; average-measure ICC ≈ 0.98 [0.96-0.99]); good-to-excellent for temporal and parietal lobes (average-measure ICC ≈ 0.83-0.84); moderate-to-good for hippocampus and total brain volume (TBV) (average-measure ICC ≈ 0.79-0.81), with only moderate single-measure agreement for TBV (ICC ≈ 0.51); and
Abstract
Background/Objectives: Automated brain volumetry is increasingly integrated into the work-up of several neurological disorders, yet between-software variability may limit the interchangeability of absolute measures. This study aimed to assess inter-software variability, agreement, and interchangeability among four clinically available AI-based brain volumetry tools. Methods: We conducted a single-center, retrospective comparison of four clinically available tools (Neurophet AQUA®, icobrain dm®, mdbrain®, Pixyl®) applied to identical 3D T1-weighted MRI examinations (IR-FSPGR, 1 mm isotropic) acquired at 3 T in 47 adults referred for tremor evaluation. Absolute volumes (mL) were extracted for hippocampus, temporal, parietal, and frontal lobes, lateral ventricles, and total brain volume; the occipital lobe was analyzed where reported (three tools). Region-wise complete-case analyses were performed. Repeated-measures ANOVA with Bonferroni post hoc tests assessed systematic differences, and intraclass correlation coefficients (two-way mixed, consistency) were reported as single- and average-measure with 95% CIs to quantify agreement. Results: Across regions, all tests were significant (p < 0.001), indicating method-dependent scale offsets typically on the order of ~20-40%. A consistent pattern emerged: icobrain dm® yielded the largest absolute volumes, Neurophet AQUA® the lowest, mdbrain® tended to be lower for parietal measurements, and Pixyl® was generally intermediate. Agreement was structure-dependent: excellent for lateral ventricles (single-measure ICC ≈ 0.92 [0.85-0.96]; average-measure ICC ≈ 0.98 [0.96-0.99]); good-to-excellent for temporal and parietal lobes (average-measure ICC ≈ 0.83-0.84); moderate-to-good for hippocampus and total brain volume (TBV) (average-measure ICC ≈ 0.79-0.81), with only moderate single-measure agreement for TBV (ICC ≈ 0.51); and lowest for the frontal lobe (single-measure ICC ≈ 0.43 [0.23-0.65]; average-measure ICC ≈ 0.75 [0.54-0.88]). In the occipital lobe (three tools), Neurophet AQUA® yielded substantially smaller values than icobrain dm® and mdbrain® (p < 0.0001). Conclusions: Overall, absolute volumetric outputs are not directly interchangeable across platforms, but relative subject ranking is largely preserved; platform-consistent analysis is advisable for longitudinal monitoring, and cross-site studies should implement calibration/harmonization before pooling data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement and longitudinal repeatability of established brain volumetry pipelines across healthy controls, multiple sclerosis, and Alzheimer's disease.Frontiers in neuroscience · 2026
- Regional correspondence between visual Fazekas ratings and AI-derived white matter hyperintensity burden in acute ischemic stroke: a retrospective cross-sectional studyBMC Neurology · 2026
- A Belgian study assessing relapsing multiple sclerosis activity through automated magnetic resonance imaging volumetry.Neurodegenerative disease management · 2026
- Distributional Characterization of ICV-Normalized Regional Brain Volumes in Alzheimer's Disease.Life (Basel, Switzerland) · 2026
- Inter-software variability of Centiloid quantification in amyloid PET: A head-to-head comparison of five software platforms.Alzheimer's & dementia (Amsterdam, Netherlands) · 2026
- Selective White Matter Volume Reduction in Neurologically Asymptomatic Adults with Obesity: An AI-Based MRI Volumetric Study.Brain sciences · 2026