Regional correspondence between visual Fazekas ratings and AI-derived white matter hyperintensity burden in acute ischemic stroke: a retrospective cross-sectional study
Qiaoqiao Liao, Yue Tang, Hailong Lian, Liping Wang, Jinping Liu
Key points
From the paper's conclusion- We quantified regional and total visual–AI correspondence, inter-reader reliability, and high-burden concordance in acute ischemic stroke.
Abstract
Background Visual Fazekas ratings assess white matter hyperintensity (WMH) severity, whereas artificial intelligence (AI)-derived segmentation provides continuous measurements. We quantified regional and total visual–AI correspondence, inter-reader reliability, and high-burden concordance in acute ischemic stroke. Methods We included 361 patients with acute ischemic stroke undergoing T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) magnetic resonance imaging (MRI). Two readers independently assigned periventricular, deep, and total Fazekas scores. AI-derived WMH volumes were normalized to intracranial volume. Spearman correlations, HC3-robust linear trends, quadratic weighted κ, binary agreement, and a 2 × 3 threshold-sensitivity matrix were evaluated. Visual high burden was total Fazekas score ≥ 4; AI high burden was the cohort-specific upper third of total WMH/intracranial volume (1.20%). Results Median age was 67 years, and 258 patients (71.5%) were men. Reader 1 ratings correlated strongly with AI-derived periventricular WMH (ρ = 0.840, 95% CI 0.807–0.866) and total WMH (ρ = 0.880, 95% CI 0.851–0.902), and moderately with deep WMH (ρ = 0.588, 95% CI 0.514–0.656; all P < 0.001). Inter-reader reliability was excellent (quadratic weighted κ = 0.869–0.926). Under the primary thresholds, 326 of 361 patients agreed (90.3%), with κ = 0.781 (95% CI 0.708–0.847). Reader 2 replication was similar; across alternative thresholds, κ ranged from 0.462 to 0.801. Conclusions Visual Fazekas ratings showed strong correspondence with AI-derived WMH burden, especially for total and periventricular disease. Weaker deep-WMH correspondence and threshold-dependent discordance indicate that visual ratings and quantitative measurements are complementary rather than interchangeable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Accuracy of GPT-5 in Detecting and Localizing Acute Ischemic Stroke on Isolated Diffusion-Weighted Imaging: A Retrospective Case-Control Study.Journal of clinical medicine · 2026
- Artificial Intelligence in Cerebral Small Vessel Disease Imaging: A Study-Level Cross-Sectional Analysis of Validation Status and Clinical Applicability.Journal of imaging informatics in medicine · 2026
- Norms for Automatic Estimation of White Matter Hyperintensities Burden: LST-AI Service in neuGRID.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence for white matter hyperintensity segmentation: performance, determinants, and clinical implications.Frontiers in aging neuroscience · 2026
- Visual rating versus volumetric segmentation of white matter hyperintensities for cognitive assessment: a memory clinic-based comparison and systematic review.Cerebral circulation - cognition and behavior · 2026
- AI-assisted hemorrhage detection following endovascular stroke treatment: a retrospective diagnostic accuracy studyNeurological Research and Practice · 2026