CadTool: An End-to-End Semiconductor Detector Simulation Tool

Hugo Allaire, José Ferreira Sousa, David Baudin, Miho Katsuragawa, Rémy Le Breton, Olivier Limousin, Aline Meuris, Tadayuki Takahashi,

Computational

Key points

From the paper's conclusion
  • We present CadTool, an end-to-end simulation tool that combines GATE 10/Geant4 for photon transport and energy deposition with the SolidStateDetectors.jl library for electric-field calculation, charge transport and signal induction, followed by a modular electronics-readout model that produces digitized data in the same format as the corresponding experimental detector.

Abstract

CdTe and CdZnTe (CZT) sensors have attracted significant attention over the past 25 years as room-temperature semiconductor detectors for hard X-ray and γ-ray detection, with applications in astrophysics, medical imaging, non-destructive testing, and nuclear security. Their appeal lies in the combination of compact form factor, high stopping power, wide bandgap and favourable charge-transport properties. We present CadTool, an end-to-end simulation tool that combines GATE 10/Geant4 for photon transport and energy deposition with the SolidStateDetectors.jl library for electric-field calculation, charge transport and signal induction, followed by a modular electronics-readout model that produces digitized data in the same format as the corresponding experimental detector. We compare simulations with measurements from three CdTe detector configurations, simulated with a single set of charge-transport parameters: a 1 mm thick pixel detector and 1–2 mm thick double-sided strip detectors, all with a 250 µm pitch, under 241Am illumination, and a 2 mm thick pixel detector with an 800 µm pitch irradiated with 133Ba and 137Cs up to 662 keV. For the pixel detector and the 1 mm strip detector, the measured and simulated energy spectra below 70 keV differ by 7–12 % of their events, and the dominant one- and two-electrode multiplicity classes agree within 20%. At 662 keV, the inter-pixel charge loss agrees within their respective uncertainties, the mean cluster size within 1.2% and the multiplicity fractions within 1.73%. CadTool is intended to support the design and optimisation of future detector and Application Specific Integrated Circuit (ASIC) systems, provide detailed detector-response models for larger-scale simulations, generate synthetic datasets, and improve the understanding of charge-transport and signal-formation processes in semiconductor detectors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers