Setting-up a new Timepix4-based computed tomography system with a CdTe sensor for cultural heritage applications: challenges and preliminary results
M. Bettuzzi, V. Cavallini, C. Riccardizi, M.P. Morigi, N.V. Biesuz, M. Andreotti, I. Ballantini, M. Fiorini
Key points
From the paper's conclusion- Preliminary results of energy-selective CT are presented, and the potential, limitations and current challenges of the system are discussed.
Abstract
A new computed tomography (CT) system based on a Timepix4 ASIC has been designed and built through a collaboration between the Department of Physics of the University of Ferrara and the Department of Physics and Astronomy of the University of Bologna. A detector with spectroscopic capabilities was developed by coupling a Timepix4 ASIC to a CdTe semiconductor layer. The tomographic system incorporates this detector and a low-power microfocus X-ray tube, together with two goniometric cradles for alignment and a precision rotation stage. A dual-axis translation system moves the detector head within a vertical plane, enabling the inspection of a larger area. The readout electronics, based on the IDAQ board, together with the DataPix4 software, enable photon energy thresholding and binning, thereby allowing multi-energy CT. This article describes the system design and configuration, detector characterization, the scanning procedure and the data processing workflow. Preliminary results of energy-selective CT are presented, and the potential, limitations and current challenges of the system are discussed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Synergistic Time‐Delay Integration X‐Ray Imaging with Pixelated Cs 3 Cu 2 I 5 Scintillators for High‐Fidelity In‐Line InspectionAdvanced Optical Materials · 2026
- CadTool: An End-to-End Semiconductor Detector Simulation ToolCondensed Matter · 2026
- Fundamental characterisation of CdZnTe (CZT) and CdTe as sensor materials for the JUNGFRAU charge-integrating ASICJournal of Instrumentation · 2026
- Study of the intra-pixel timing resolution of planar silicon sensors using the TDCpix ASICarXiv · 2026
- Defect-assisted space-charge accumulation drives electric-field reconstruction in cadmium zinc telluride x-ray detectorsApplied Physics Letters · 2026
- Ultra-high spatial resolution at photon-counting computed tomography: technical insights and sustainable applications in cardiothoracic imagingEuropean Radiology Experimental · 2026