Glucose Sensor Using Fe3O4 Functionalized MXene Nanosheets as a Promising Sensing Platform: Exploring the Potential of Electrochemical Detection of Glucose
Yu Yang, Danning Li, Changchang Zheng, Ling Zhang, Xuwei Chen
Shenyang Normal University · Northeastern University
Key points
From the paper's conclusion- The sensor showed a bilinear glucose response in the ranges of 0.05–15 mM, with sensitivity of 120.47 μA·mM−1·cm−2 and a detection limit of 38 μM.
Abstract
Enzymatic electrochemical sensors are promising for real-time glucose monitoring due to their high sensitivity and continuous detection capability. In this work, a magnetic Fe3O4@MXene nanocomposite was synthesized hydrothermally. The introduction of Fe3O4 not only reduced MXene’s inherent negative surface charge, improving interaction with glucose oxidase (GOD), but also formed a porous structure that enhances enzyme immobilization via physical adsorption. Based on these properties, a Fe3O4@MXene/GOD/Nafion/GCE electrode was fabricated. The composite’s high specific surface area, excellent conductivity, and good biocompatibility significantly promoted the direct electron transfer (DET) of GOD. Meanwhile, the apparent electron transfer rate constant (ks) was calculated to be 9.57 s−1, representing a 1.26-fold enhancement over the MXene-based electrode (7.57 s−1) and confirming faster electron transfer kinetics. The sensor showed a bilinear glucose response in the ranges of 0.05–15 mM, with sensitivity of 120.47 μA·mM−1·cm−2 and a detection limit of 38 μM. It also exhibited excellent selectivity, reproducibility and stability. Satisfactory recovery rates were achieved in artificial serum samples while demonstrating comparable detection performance to commercial blood glucose meters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A wearable sensor integrating a MXene-PLL-GOx-modified electrode and a Janus nanofibrous membrane for electrochemical monitoring of sweat glucose.Talanta · 2026
- Miniaturized integrated electrochemical sensor using Ag@MoS2/graphene oxide aerogel for implantable non-enzymatic glucose monitoringScientific Reports · 2025
- Engineered AuNPs/fMWCNT Nanocomposite Electrodes for High‐Sensitivity Methylglyoxal Sensing in Saliva and Sweat for Non‐Invasive Diabetes MonitoringAdvanced Healthcare Materials · 2026
- MXene-Based Electrochemical Detection of Alzheimer’s Disease-Associated BiomarkerACS Applied Nano Materials · 2026
- Interface-Programmed Growth of High-Aspect-Ratio 1D Ni-MOF Nanofibers on MXene for Wearable Enzyme-Free Glucose Sensing.ACS applied materials & interfaces · 2026
- Unlocking the Potential of MXene‐Based Electrochemical Biosensors: A Review of Biofunctionalization Strategies and Biosensing PrinciplesAdvanced Materials Technologies · 2026