Interface-Programmed Growth of High-Aspect-Ratio 1D Ni-MOF Nanofibers on MXene for Wearable Enzyme-Free Glucose Sensing.
Dandan Zhang, Hongjiang Li, Shushuai Zhu, Gajanan A Bodkhe, Shoukun Yu, Chen Wang, Mulin Qu, Se Hyun Kim,
College of Mechanical and Electrical Engineering, Qingdao University, 308 Ningxia Road, Qingdao, Shandong266071, China. · School of Mechanical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do38541, Republic of Korea.
Key points
From the paper's conclusion- Here, we address these challenges by combining strong interfacial anchoring on a conductive template with surfactant-assisted growth control to engineer high-aspect-ratio (∼100) 1D Ni-TCPP MOF nanofibers as an active shell on MXene-NH2.
Abstract
Noninvasive wearable glucose sensors capable of real-time sweat analysis offer a less discomforting alternative for long-term monitoring in patients with diabetes. However, practical implementation remains challenging. Major barriers include insufficient catalytic sensitivity to quantify the low glucose levels in sweat, limited compatibility between nanomaterial synthesis and scalable manufacturing processes, and the lack of a biofluid microenvironment suitable for enzyme-free electrochemical sensing. Here, we address these challenges by combining strong interfacial anchoring on a conductive template with surfactant-assisted growth control to engineer high-aspect-ratio (∼100) 1D Ni-TCPP MOF nanofibers as an active shell on MXene-NH2. In contrast to conventional electrospinning-assisted approaches, the resulting 1D MOF shell is polymer-template-free and thus avoids insulating scaffold components. The resulting fluffy, self-supporting Ni-MOF@MXene architecture is inherently compatible with printed electronics, enabling large-area fabrication of wearable enzyme-free glucose-sensing patches. To overcome the constraints of enzyme-free sensing in physiological biofluids, we further develop an integrated system that combines microfluidics with a NaOH/Nafion/PVA alkaline sustained-release membrane, establishing a localized alkaline microenvironment within sweat to enable continuous analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Metal-organic framework-based wearable electrochemical glucose sensors for sweat analysis: materials design, sensing mechanisms, and future perspectives.RSC advances · 2026
- A wearable sensor integrating a MXene-PLL-GOx-modified electrode and a Janus nanofibrous membrane for electrochemical monitoring of sweat glucose.Talanta · 2026
- Interfacial Engineering of Printable MOF/MXene Heterostructured Inks for High-Performance Wearable Ammonia Sensors.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Scalable Self-Powered Sweat Lactate Patches Based on Bulk-Catalytic MXene/NiO for Wide-Range Detection.Small (Weinheim an der Bergstrasse, Germany) · 2026
- 3D-printed hollow microneedle-based electrochemical sensor for wireless glucose monitoringThe Analyst · 2026
- A Fully Integrated Wearable Microfluidic Electrochemical Sensor with Ultrasonic Connecting and Hot-Pressing Bonded Multilayer Structure for Sweat Biomarker AnalysisAnalytical Chemistry · 2025