Buildings

Architectural Coordination of Wall Reflectance Zoning and Window Design in Deep-Plan University Classrooms

Binyi Hong, Peize Li, Yikang Sun

Key points

From the paper's conclusion
  • This study tests whether wall reflectance zoning improves deep-plan classroom daylight when mean wall reflectance is held at 0.55.

Abstract

Interior reflectance is often treated as a uniform input in architectural daylight studies, leaving the effect of its spatial allocation unclear. This study tests whether wall reflectance zoning improves deep-plan classroom daylight when mean wall reflectance is held at 0.55. A 96-case annual Radiance experiment combines four window-to-wall ratios, four orientations, and six neutral diffuse-reflectance schemes in a Nanjing classroom. The high-reflectance rear wall scheme increased rear-zone daylight autonomy by 3.97 percentage points and median minimum-to-mean uniformity by 0.020, averaged across 16 matched aperture–orientation pairs. Its modeled lighting-demand reduction was 0.130 kWh m−2 y−1 under ideal sensor-level dimming. Supplementary analyses examine occupancy assumptions, grouped lighting control, threshold choices, room depth, shading, and numerical sensitivity. The results identify reflectance redistribution as a modest spatial refinement rather than a substitute for aperture or solar-control design. They do not establish improved occupant comfort, field-validated performance, or lower total building energy use. Architectural application requires checking the particular room, façade, finish specification, and lighting controls.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers