Differentiated Design of Dormitory Buildings Based on Orientation, Focusing on Thermal and Daylighting Performance
Yuanxin Yue, Jingyu Yuan, Sheng Yao, Jialin Lan, Xinshuo Zhang
Key points
From the paper's conclusion- South-facing units are more sensitive to the window solar heat gain coefficient, while north-facing units are more sensitive to the window thermal transmittance. (2) Window Types 8 and 5 are recommended for north- and south-facing rooms, with window-to-wall ratios of 0.30 and 0.39, respectively. (3) Comparing three daylighting optimization scenarios reveals that high correlation does not necessari
Abstract
In university dormitory buildings composed of standardized units, units of different orientations are typically designed with identical parameters. Using a typical dormitory as the baseline, XGBoost-based models with Bayesian hyperparameter optimization were coupled with NSGA-II for multi-objective optimization. Sensitivity analysis was performed to reveal the orientation-dependent influence mechanisms of design variables and to identify the key variables affecting useful daylight illuminance (UDI), vertical illuminance at eye level (VCI), predicted percentage of dissatisfied (PPD), and energy use intensity (EUI) in south- and north-facing dormitories, with TOPSIS used for decision making. Results show that: (1) For both orientations, the window-to-wall ratio and window type are the key variables. South-facing units are more sensitive to the window solar heat gain coefficient, while north-facing units are more sensitive to the window thermal transmittance. (2) Window Types 8 and 5 are recommended for north- and south-facing rooms, with window-to-wall ratios of 0.30 and 0.39, respectively. (3) Comparing three daylighting optimization scenarios reveals that high correlation does not necessarily imply substitutability: the maximum difference in all performance indicators reached 6.75%, indicating that indicator selection affects the multi-objective optimization results. (4) The effect of wall reflectance on vertical illuminance depends on orientation, window parameters, and floor level, and is more pronounced in higher-floor rooms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Orientation-Specific Multi-Objective Optimization of Building Envelopes for University Library Reading Spaces: A Design Framework Based on Field-Calibrated Simulation and Hierarchical Decision-MakingApplied Sciences · 2026
- Orientation-Specific Multi-Objective Daylight Optimization of Office Buildings: Integrating Window Geometry and External ShadingBuildings · 2026
- Multi-Objective Optimization and Decision-Making for Differentiated Retrofitting of Existing Residential Buildings in Cold Climate RegionsBuildings · 2026
- A Parametric Decision-Support Method for Window-to-Wall Ratio Based on Visual and Thermal ComfortBuildings · 2026
- Shaping Indoor and Outdoor Performance: Multi-Objective Optimization of Residential Building GeometrySustainability · 2026
- Explainable AI for Multiobjective Design Decisions in University Teaching BuildingsBuildings · 2026