Optimizing the lighting environment in college teaching buildings in the Changsha-Zhuzhou-Xiangtan region based on hybrid lighting patterns.
Leyan Zhang, Bi'nan Zuo, Xi Jin, Canlong Liu, Yufeng He
Department of Architecture, Hunan University of Science and Technology, School of Architecture and Design, Xiangtan, China. · Department of Architecture, Hunan University of Technology, School of Civil and Environmental Engineering, Zhuzhou, China.
Key points
From the paper's conclusion- The results indicate that all four patterns significantly enhanced daylight utilization across multiple metrics-including illuminance, spatial uniformity, daylight factor, spatial daylight autonomy, and target illuminance duration-thereby reducing dependence on electric lighting during daytime classroom operation.
Abstract
With the rapid expansion of higher education campuses in China, teaching buildings have become major contributors to lighting-related energy consumption. Most university teaching buildings adopt interior corridor layouts, in which classrooms rely primarily on single-sided daylighting, often resulting in insufficient daylight availability, particularly in north-facing spaces. Improving the lighting performance of interior corridor-type teaching buildings is therefore critical for enhancing energy efficiency and indoor environmental quality. In this study, an evaluation framework for indoor lighting environments is established, and the Chongye Teaching Building at Hunan University of Technology is selected as a representative case. Through a combination of on-site measurements and daylighting simulations, the daylighting characteristics of interior corridor-type teaching buildings in the Changsha-Zhuzhou-Xiangtan (Chang-Zhu-Tan) region are systematically analyzed. Four hybrid lighting patterns integrating natural and artificial lighting are proposed, including High-Density Layout (HDL), Medium-Density Layout (MDL), Low-Density Layout (LDL), and Targeted Layout (TL). The results indicate that all four patterns significantly enhanced daylight utilization across multiple metrics-including illuminance, spatial uniformity, daylight factor, spatial daylight autonomy, and target illuminance duration-thereby reducing dependence on electric lighting during daytime classroom operation. Through this proof of concept, the present study provides guidance and references for optimizing the luminous environment in interior-corridor classrooms under comparable architectural and daylight climate conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Synergistic Optimization of Daylighting and Thermal Performance and Heterogeneous Design Strategies for Teaching Buildings with Different Exterior-Corridor OrientationsBuildings · 2026
- Synergistic Optimization of Daylighting and Carbon Emissions in University Teaching Buildings from the Perspective of Spatial HeterogeneityBuildings · 2026
- Architectural Coordination of Wall Reflectance Zoning and Window Design in Deep-Plan University ClassroomsBuildings · 2026
- Nighttime Lighting Effect on a University Residential BuildingBuildings · 2026
- Horizontal Light Pipe System for Daylight Optimization in Deep-Plan Library Spaces in a Tropical ClimateJournal of Daylighting · 2026
- Digital Twins for indoor environmental quality optimisation: Insights from two case studiesE3S Web of Conferences · 2026