Numerical Simulation Analysis of Impact Resistance of Single-Sided Steel-Plate Concrete Structures in Nuclear Power Engineering
Youjia Zhang, Junhao Zhang, Xinwen Zhang, Xu Zhang, Yuxuan Xia
Key points
From the paper's conclusion- Overall, concrete structures with a steel plate on one side can provide reliable impact protection when an adequate steel reinforcement ratio is maintained.
Abstract
Nuclear reactors are essential components of nuclear power plants. One-sided steel-plate-concrete (OSSPC) structures are widely used in nuclear island building roofs owing to their high construction efficiency and excellent structural performance. Their radiation-shielding and impact-resistance capabilities are essential to nuclear island safety. This study investigates the impact response of OSSPC structures. A finite element (FE) model was developed in ABAQUS and validated against experimental results. The impact performance of OSSPC structures was compared with that of reinforced concrete (RC) structures with an equivalent steel reinforcement ratio. A series of parametric analyses was conducted to investigate the effects of steel plate thickness, concrete layer thickness, material strength, the impact distance-to-thickness ratio, and impact angle on the structural response. Furthermore, an analytical expression for residual velocity was derived based on the principle of energy conservation. The results show that the residual velocity of OSSPC structures is 25.9% higher than that of double-sided steel-plate-concrete structures but 5.4% lower than that of RC structures. These findings indicate that the impact resistance of OSSPC structures lies between that of the two comparison structures. Among the parameters investigated, concrete layer thickness has the most significant effect on the impact response. A 46.2% increase in concrete layer thickness reduces the residual velocity by 59.2%. By comparison, steel plate thickness, material strength, and the impact distance-to-thickness ratio have relatively minor effects on the impact response. Increasing the impact angle from 30° to 60° reduces the penetration depth by 43%, indicating that normal incidence represents the most critical loading condition. When the energy-based method is used to predict residual velocity, the average deviations from the experimental results are 22% and 18%, respectively, with the predictions generally being conservative. Overall, concrete structures with a steel plate on one side can provide reliable impact protection when an adequate steel reinforcement ratio is maintained. For structural design, normal incidence should be considered the governing loading condition. Priority should be given to increasing the concrete layer thickness, and the energy-based method can be employed to obtain conservative estimates of residual velocity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Investigation of the Out-of-Plane Impact and Shear Behavior of Steel Plate Concrete Walls for Nuclear Power ApplicationsBuildings · 2026
- Investigation of Reactor Building Structural Integrity: Heavy Equipment Fall onto Reinforced Concrete StructuresApplied Sciences · 2026
- Dynamic Response and Multiobjective Optimization of a Hybrid SCS‐GDAF Energy Absorbing Panel Under Impact LoadThe Structural Design of Tall and Special Buildings · 2026
- Study on mechanical performance experiments of modular composite slabs in nuclear engineeringEngineering Research Express · 2026
- Numerical study on the effects of structural parameters on the blast performance of U-shaped steel-encased concrete composite beamsJournal of Physics: Conference Series · 2026
- Nonstationary Stochastic Seismic Optimization of Base‐Isolated Nuclear Power Plant Equipped With Negative Stiffness Amplifying Damper Considering Dynamic Soil–Structure‐InteractionEarthquake Engineering & Structural Dynamics · 2026