Investigation of Reactor Building Structural Integrity: Heavy Equipment Fall onto Reinforced Concrete Structures
Emilija Stankutė, Remigijus Janulionis, Egidijus Babilas
Key points
From the paper's conclusion- The findings using simplified FEM models demonstrate the possible damage zones of the steam drum separator room concrete floor of the reactor building under extreme impact loading, while stresses in the reinforcement are below the yield strength of the material, and provide additional information for safety assessment and structural planning during the decommissioning of ageing RBMK facilities.
Abstract
As RBMK-type reactors reach the end of their operational lifetime, ensuring structural safety during decommissioning becomes increasingly important. This study evaluates the structural response of an RBMK reactor (High-Power Channel-type Reactor) building floor under a hypothetical accidental drop of a steam drum separator on reinforced concrete floor. Finite element analysis was employed to investigate a horizontal impact scenario in which the drum separator falls onto a rigid floor, generating a peak contact force of 368 MN. The results demonstrate that the impact produces possible localised surface damage zones to the reactor building structures and causes stress to spread into adjacent supporting walls. As heavy equipment fall might cause damage to building structures, assessing its potential consequences is important for evaluating local structural integrity during decommissioning. The findings using simplified FEM models demonstrate the possible damage zones of the steam drum separator room concrete floor of the reactor building under extreme impact loading, while stresses in the reinforcement are below the yield strength of the material, and provide additional information for safety assessment and structural planning during the decommissioning of ageing RBMK facilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Simulation Analysis of Impact Resistance of Single-Sided Steel-Plate Concrete Structures in Nuclear Power EngineeringBuildings · 2026
- Thermal Damage of Serpentine Concrete Under Microwave Volumetric Versus Muffle Furnace Surface Heating.Materials (Basel, Switzerland) · 2026
- Strategic framework for the simulation of explosive graphite failure under runaway electron incidencePlasma Physics and Controlled Fusion · 2026
- Conditional Root-Stress Exceedance of a 220 kV Disconnect Switch Under Dynamic Slurry–Boulder Debris-Flow LoadingApplied Sciences · 2026
- Physical aspects and modelling approach to a core disruptive accident in a heavy liquid metal fast reactorEPJ Nuclear Sciences & Technologies · 2026
- Numerical Investigation of the Out-of-Plane Impact and Shear Behavior of Steel Plate Concrete Walls for Nuclear Power ApplicationsBuildings · 2026