From the paper's conclusion- These results indicate good agreement with the reference data, supporting the use of the method for rapid assessment of SC walls during preliminary impact-resistant design.
Abstract
Steel plate concrete (SC) walls combine the tensile strength of steel plates with the energy-dissipation and radiation-shielding capabilities of concrete, providing greater blast resistance than conventional reinforced-concrete structures. Although SC walls are increasingly used in nuclear power plant shielding structures, simple methods for predicting their dynamic response under low-velocity impact remain limited. In this study, we developed an ABAQUS finite element model of SC walls under drop-weight impact and validated it against published experimental data. Parametric analyses show that residual displacement is most sensitive to the thickness of the concrete core. Increasing the core thickness from 1000 to 1200 mm reduces residual displacement by 38.5%. Reducing the span-to-thickness ratio (the stud spacing-to-plate thickness ratio) from 50 to 37.5 decreases residual displacement. However, a further reduction to 25 sharply increases the peak impact force. Thus, 37.5 provides an optimal balance between these responses. Based on yield-line theory and the concrete punching-shear failure mechanism, we derived a multilinear resistance function that accounts for flexural yielding, punching-shear cracking, ultimate capacity, and post-failure resistance. We also developed a corresponding method for calculating stiffness. We incorporated the resistance function and stiffness method into an equivalent single-degree-of-freedom (SDOF) system and solved the equations of motion to rapidly predict maximum and residual displacements. We validated the proposed method against experimental data and finite element simulations. The mean ratios of calculated to reference displacements were 1.073 for maximum displacement and 0.978 for residual displacement. These results indicate good agreement with the reference data, supporting the use of the method for rapid assessment of SC walls during preliminary impact-resistant design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Simulation Analysis of Impact Resistance of Single-Sided Steel-Plate Concrete Structures in Nuclear Power EngineeringBuildings · 2026
- Numerical study on the effects of structural parameters on reinforced concrete shear walls with openings under blast loadingJournal of Physics: Conference Series · 2026
- Numerical study on the effects of structural parameters on the blast performance of U-shaped steel-encased concrete composite beamsJournal of Physics: Conference Series · 2026
- Dynamic Response and Multiobjective Optimization of a Hybrid SCS‐GDAF Energy Absorbing Panel Under Impact LoadThe Structural Design of Tall and Special Buildings · 2026
- Experimental and Theoretical Investigations of the Shear Resistance of SCS Composite Structures with Web OpeningsJournal of Structural Engineering · 2025
- Advanced energy-based and two-degree-of-freedom analytical modeling of reinforced concrete slabs subjected to low-velocity impact and equivalent blast loadingScientific Reports · 2026