From the paper's conclusion- The research demonstrates the necessity of CFD modeling to prevent aerodynamic failures and design reliable sub-floor ventilation systems.
Abstract
Sub-floor ventilated cavities represent a widely used remediation method for structural moisture reduction, yet their performance is often assumed to be automatically functional without evaluating internal airflow dynamics. This study presents a detailed Computational Fluid Dynamics (CFD) analysis supplemented by in situ experimental monitoring to evaluate cavity airflow performance and optimize parameters for moisture control in building structures. The CFD simulations demonstrated high predictive accuracy, revealing that systems strictly reliant on natural ventilation exhibit severe instability, with airflow velocities dropping to near-zero values during calm wind. Parametric evaluations confirmed the critical impact of protective grille permeability: grilles with a low free area ratio generate significant pressure drops that virtually disable air exchange, whereas higher permeability values are required to minimize resistance. Furthermore, effective drying requires targeted airflow along moist structural surfaces to enable continuous evaporation, whereas radon mitigation primarily relies on establishing a negative pressure field relative to the interior to prevent radon ingress. Improper mechanical ventilation configurations without adjusting all flow pathways can induce backdraft effects, disrupt internal airflow distribution, and fail to maintain the required negative pressure field, thereby compromising the moisture reduction process. The research demonstrates the necessity of CFD modeling to prevent aerodynamic failures and design reliable sub-floor ventilation systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on radon mitigation performance of building foundations with adsorption layers.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Experimental validation and CFD analysis of ventilation-dependent thoron distribution at breathing height in a full-scale mud test house.Journal of environmental radioactivity · 2026
- Deformation of surrounding rocks in salt caverns in compressed air energy storage plants: Insights from laboratory experiments and numerical simulationsTunnelling and Underground Space Technology · 2025
- Radon Diffusion Coefficients of Barrier Materials: A Critical Review of Measurement, Modeling, and Laboratory-to-Field Interpretation.Materials (Basel, Switzerland) · 2026
- Computational Hygrothermal Analysis of External Wall Behavior in Naturally Ventilated and Air-conditioned Historical Buildings in ThailandNakhara Journal of Environmental Design and Planning · 2026
- Computational Fluid Dynamics in Hybrid Passive–Active Heat Recovery Systems for High-Performance Buildings: A Critical ReviewGlobal Decarbonisation · 2026