Journal of environmental radioactivity

Experimental validation and CFD analysis of ventilation-dependent thoron distribution at breathing height in a full-scale mud test house.

Rajat Parkash, Sandeep D Kanse, Tarun Kumar Agarwal, R P Chauhan

School of Advanced Sciences and Languages, VIT Bhopal University, Sehore, 466114, India. Electronic address: rajatparkash@vitbhopal.ac.in. · Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India.

Key points

From the paper's conclusion
  • The results demonstrate persistent near-wall concentration enhancement and rapid decay toward the room interior, with spatial non-uniformity decreasing as ventilation increases.

Abstract

Thoron (220Rn) emitted from thorium-bearing building materials exhibits strong spatial non-uniformity indoors, making exposure assessment highly sensitive to ventilation and airflow patterns. This study investigates the role of ventilation in controlling thoron transport, spatial distribution, and breathing-zone exposure using a validated Computational Fluid Dynamics (CFD) framework combined with experimental measurements in a full-scale mud test house representative of traditional building construction. Experimentally measured thoron exhalation rates from interior surfaces were applied in the CFD model as surface-flux boundary conditions, and the CFD model was validated against multi-point thoron concentration measurements under ventilation rates ranging from 0.73 to 15 h-1. The results demonstrate persistent near-wall concentration enhancement and rapid decay toward the room interior, with spatial non-uniformity decreasing as ventilation increases. Analysis at breathing height (1 m) reveals a transition in transport behavior: diffusion-dominated decay under low ventilation (≤2.5 ACH) and a two-zone structure at higher ventilation (≥5 ACH), comprising a steep near-wall gradient and a well-mixed interior region driven by advective airflow. A two-region exponential model quantifies this behavior and shows that characteristic decay lengths increase approximately linearly with ventilation. From a building-performance perspective, ventilation primarily attenuates peak breathing-zone concentrations rather than room-average levels, highlighting the importance of ventilation layout, occupant position, and spatial heterogeneity in indoor pollutant exposure assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts