Computational Hygrothermal Analysis of External Wall Behavior in Naturally Ventilated and Air-conditioned Historical Buildings in Thailand
Sarin Pinich, Atch Sreshthaputra
Chulalongkorn University
Key points
From the paper's conclusion- The findings indicate that in air-conditioned historical buildings, water content in the middle and bottom sections of the upper exterior wall is influenced by dry, lower-temperature indoor conditions.
Abstract
Moisture in historical buildings has long been a significant problem in Thailand, causing damage to structural elements, wall materials, and indoor air quality. While some issues are attributed to inherited structural systems, many result from changes in space use, particularly the introduction of air-conditioning, which alters hygrothermal performance. This study examines heat and moisture transfer in historical buildings using computational hygrothermal analysis (WUFI), comparing air-conditioned and naturally ventilated cases, with and without wall-cutting interventions, in Thailand’s hot-humid climate. The results present the average water content (kg/m³) in exterior walls across three upper sections and one lower section under both conditions. The findings indicate that in air-conditioned historical buildings, water content in the middle and bottom sections of the upper exterior wall is influenced by dry, lower-temperature indoor conditions. The reduced relative humidity of conditioned air promotes higher evaporation, lowering the damp rise height and reducing water content by 2.83 and 5.13 kg/m³ in the middle and bottom sections of the upper wall, respectively, compared with naturally ventilated cases. The air-conditioning system has only a slight effect on the hygrothermal behavior of retrofitted walls after wall-cutting interventions, with an approximately 2 kg/m³ higher water content across all upper sections in the conditioned case compared with the naturally ventilated case. Meanwhile, wall cutting has a greater effect in unconditioned spaces, with larger reductions in water content above the cut but increased moisture below due to redistribution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Moisture-Related Risks in Internally Insulated Historic Field Stone Masonry Walls: A Long-Term Hygrothermal Assessment Under Past and Future ClimateBuildings · 2026
- The Significance of Using Temperature-Dependent Material Properties in Hygrothermal Performance Assessment of Exterior Wall SystemsBuildings · 2026
- A Damage-Spectrum Framework for Specifying the Indoor Climate of Historic BuildingsBuildings · 2026
- Long-Term Indoor Hygrothermal Performance at Room Level in Occupied Residential Apartments Under a Hot Arid Coastal Climate: Implications for Sustainable Building PerformanceSustainability · 2026
- Hygrothermal Performance of Exterior Wall Assemblies Under Wind-Driven Rain Across China’s Thermal ZonesBuildings · 2025
- Building envelope materials, indoor environmental quality and public-health relevance in Kuwait: a narrative review of exposure pathways in a hot-arid climate.Frontiers in public health · 2026