Assessment and Improvement Strategies for the Winter Indoor Thermal Environment of Temporary Construction-Site Buildings in Cold Regions
Hai Zheng, Wen-Lai Li, Hong-Xia Yang, Wei-Zheng Liu
Key points
From the paper's conclusion- This study investigated typical office and dormitory temporary buildings in Yan’an, China, using 48-h winter field measurements and 50 thermal comfort questionnaires to identify indoor thermal environment problems, followed by a calibrated and validated EnergyPlus model.
Abstract
Temporary construction-site buildings in cold regions often suffer from poor indoor thermal environments and high heating energy consumption, while field-based studies and cost-effective improvement strategies remain limited. This study investigated typical office and dormitory temporary buildings in Yan’an, China, using 48-h winter field measurements and 50 thermal comfort questionnaires to identify indoor thermal environment problems, followed by a calibrated and validated EnergyPlus model. The results showed that the average indoor air temperature was only 3.6 °C under unheated conditions, with envelope interior surface temperatures below 5 °C. Under air-conditioning heating, the average indoor temperature increased to 15.3 °C but remained below the basic winter requirement. Office and dormitory buildings showed different heating demand patterns, supporting differentiated heating schedules. Compared with 24-h continuous heating, the recommended intermittent scenarios reduced heating load by 888.10 and 119.42 kWh, respectively; compared with baseline operation, reductions were 13.2% and 5.7%. Window and envelope improvements reduced heating load with diminishing marginal benefits. A 12-mm air layer was recommended for thermally broken aluminum double glazing, with rock wool thicknesses of 105 mm, 100 mm, and 95 mm for walls, roof, and floor, respectively, reducing heating load by 13.68% and 20.48% for office and dormitory buildings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CFD Assessment of Thermal Comfort and Heating Demand in Courtrooms Under Envelope Retrofit ScenariosThermo · 2026
- Thermal comfort in office-to-residential adaptive reuse: A Swedish case studyE3S Web of Conferences · 2026
- Passive thermal performance of vernacular dwellings in the hot summer and cold winter region of Southern Henan, ChinaCase Studies in Thermal Engineering · 2026
- Evaluation and Sustainable Optimization Design of Indoor Thermal Environment in Traditional Tujia Dwellings in Summer in Northwestern Hunan, ChinaSustainability · 2026
- Seasonal Asymmetry in Thermal Adaptation Among Residents of Traditional Dwellings in Eastern Hunan: An aPMV-Based Field Study of Winter AdaptationBuildings · 2026
- Sensitivity of Heating Energy Demand to Indoor Temperature, Effective Air-Change Rate, and Climate: A TRNSYS Case Study Supporting Sustainable Operation of a Multi-Apartment BuildingSustainability · 2026