A Keyhole-Shaped Microwave Resonator for Hematocrit Sensing Toward Dengue Monitoring.
Suhail Asghar Qureshi, Zuhairiah Zainal Abidin, Gameel Saleh
Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, Parit Raja 86400, Malaysia. · Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia.
Key points
From the paper's conclusion- This compact microwave sensor is a candidate framework for point-of-care HCT monitoring, subject to validation on blood.
Abstract
Rapid and continuous monitoring of blood hematocrit (HCT) levels is critical for detecting hemoconcentration and plasma leakage associated with dengue virus progression. This paper presents a label-free, metamaterial-based microwave sensor designed to detect dielectric variations corresponding to changes in HCT. The proposed structural design utilizes a keyhole-shaped resonator. The sensor's transmission coefficients (S21) were numerically evaluated using simulated dielectric properties representing an extended modelled HCT range of 0% to 80%. The simulated analysis demonstrates a systematic response, linear in resonance frequency (R2 = 0.996) and curved in magnitude (R2 = 0.812), achieving a resonance shift sensitivity of 4.5 MHz/%HCT and a magnitude sensitivity of 0.0599 dB/%HCT. Based on these simulations, a 20% relative rise from a patient's baseline HCT (assuming = 50%) corresponds to a 45 MHz resonance shift and a -0.599 dB magnitude deviation. As an initial proof of concept, the prototype was tested with alcohol-water mixtures. Over 0-40% alcohol the resonance moved to lower frequencies, whereas above 60%, it reversed. This compact microwave sensor is a candidate framework for point-of-care HCT monitoring, subject to validation on blood.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design of an Ultra-Sensitive Multi-Resonant Moore Fractal SRR Microwave Sensor for Non-Invasive Blood Glucose MonitoringSensors · 2026
- Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoringScientific Reports · 2026
- Hand-powered micro-slit-gated microfluidics for concurrent blood typing and hematocrit estimation.Biosensors & bioelectronics · 2026
- Wearable Textile Microwave Sensor for Wrist Pulse Wave and Heart Rate MonitoringIEEE Sensors Journal · 2026
- H ygieia : A Wearable Metamaterial Patch for Calibration-free Carotid Hemodynamics MonitoringProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- A Multifrequency Millimeter-Wave CMOS Sensor for Non-Invasive Continuous Glucose Monitoring Using UMC 0.18 μm Technology.Biosensors · 2026