Quantification of Biliverdin, Bilirubin and Bilirubin Glucuronide in Micro-Samples of Animal Blood.
Paola Sist, Federica Tramer, Marco Stebel, Donatella Volpatti, Sabina Passamonti
Department of Life Sciences, University of Trieste, Via Giorgieri 1, 34127 Trieste, Italy. · Department of Agricultural, Food, Environmental and Animal Sciences, University of Udine, Via Sondrio, 2/A, 33100 Udine, Italy.
Key points
From the paper's conclusion- We applied the HUG assay for the nanoscale analysis of biliverdin, bilirubin, and bilirubin glucuronide.
Abstract
Circulating bile pigments are routinely measured in human and veterinary medicine, toxicology, pharmacology, and biomedical studies, as they are consolidated biomarkers of liver dysfunction and hemolysis and emerging biomarkers of biological responses to stress. This study was performed to extend bile pigment analysis from plasma to microvolumes of whole blood not only to simplify the pre-analytical steps but also to surmount the bottleneck of limited blood volume available for withdrawals in screening and monitoring. We applied the HUG assay for the nanoscale analysis of biliverdin, bilirubin, and bilirubin glucuronide. HUG is a chimeric protein expressing the UnaG domain that emits fluorescence upon binding bilirubin. This study shows that, under specific conditions, the HUG assay enables quantification of the three bile pigments in rat and fish whole blood. Moreover, quantification is equivalent in blood, plasma and serum. This approach skips pre-analytical steps, reduces errors and time to analysis, thereby facilitating research of circulating bile pigments in animalia while preserving the possibility of comparing new data with historical sets of clinical chemistry data in the literature.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D nanoporous hydrogel-integrated portable platform for pretreatment-free, rapid multiplexed detection of small-molecule biomarkers in whole blood.Talanta · 2026
- A Noncovalent Fluorescent Probe for Dynamic Monitoring of Hemoglobin Accumulation in Living Cells.Luminescence : the journal of biological and chemical luminescence · 2026
- Whole blood hemolysis detection on the GEM® Premier™ 7000: performance across hemoglobin A, S, and F.Clinical chemistry and laboratory medicine · 2026
- Matrix Effects on the Quantification of NanoLuc Bioluminescence in Ex Vivo Organ Homogenates.Sensors (Basel, Switzerland) · 2026
- Enzyme-cascade-amplified colorimetric biosensing platform for sub-nanomolar methylmercury in environmental watersRSC Advances · 2026
- Visual biosensing of bioaccessible mercury in aquatic environments using chromoprotein-based whole-cell sensors.Ecotoxicology and environmental safety · 2026