Orthopaedic Implants in the Oncologic and Irradiated Bone Environment: A Review.
Nikolay Cherkezov, Georgi Enev, Georgi Raykov, Nikolay Dimitrov, Dimitar Tenev
Specialized University Hospital for Active Treatment in Orthopaedics "Prof. Boycho Boychev", Medical University of Sofia, 1614 Sofia, Bulgaria. · Department of Consultation Liaison Psychiatry and Psychosomatic Medicine, University Hospital Zurich, 8091 Zurich, Switzerland.
Key points
From the paper's conclusion- Throughout, evidence is labelled by its source—oncologic, extrapolated, or preclinical—and the comparative studies still needed are specified.
Abstract
Patients who require an orthopaedic implant after cancer treatment present four linked problems: a bone bed damaged by radiotherapy or chemotherapy, large reconstructions under high mechanical load, a high risk of infection, and hardware that degrades the imaging and radiotherapy planning on which oncologic follow-up depends. This narrative review examines how each problem alters implant performance and which design responses have clinical support. Radiotherapy roughly doubles dental implant failure, is associated with loosening, infection, and periprosthetic fracture after arthroplasty, and leads to non-union in most radiation-associated femoral fractures treated by internal fixation. Deep infection affects about one in ten tumour endoprostheses. Additively manufactured porous titanium and porous tantalum support bone ingrowth, but follow-up rarely exceeds five years, and their large surface area may favour bacterial colonisation. Silver, iodine, and antibiotic-loaded hydrogel coatings are associated with fewer infections in observational studies, with low certainty. Carbon-fibre-reinforced polyetheretherketone (PEEK) reduces imaging artefact and dose perturbation, and biodegradable magnesium avoids hardware removal, but neither has a proven advantage in oncologic reconstruction. Throughout, evidence is labelled by its source-oncologic, extrapolated, or preclinical-and the comparative studies still needed are specified.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface engineering and coatings for metallic orthopaedic implants: an integrative review of biological performance and clinical translationFrontiers in Medical Engineering · 2026
- Effect of Implant Surface and Radiation Dose on Crestal Bone Loss in Irradiated Patients: 1-Year Preliminary Outcomes.The Journal of craniofacial surgery · 2026
- Study on the influence of fixed dental prostheses on radiotherapy dose distribution based on dual-layer detector spectral CT imaging.Frontiers in oncology · 2026
- Sternal Reconstruction Utilizing a Custom 3D-Printed Polyetherketoneketone Implant.Annals of thoracic surgery short reports · 2026
- Role of polyetheretherketone (PEEK) in arthroplasty and orthopaedics: a review of biomechanical properties, surface modifications, and clinical outcomesEuropean Journal of Orthopaedic Surgery & Traumatology · 2026
- Proximal Femoral Replacement Outcomes for Oncologic Versus Non-Oncologic Indications: A Systematic Review and Meta-Analysis.The Journal of arthroplasty · 2026