Role of polyetheretherketone (PEEK) in arthroplasty and orthopaedics: a review of biomechanical properties, surface modifications, and clinical outcomes
Raju Vaishya, Abhishek Vaish, Akash Dubey, Karthik Vishwanathan, Abid Haleem, Mohd Javaid, Filippo Migliorini
Indraprastha Apollo Hospitals · KM Shah Dental College and Hospital
Key points
From the paper's conclusion- While PEEK shows promise in orthopaedic applications, further research is necessary to establish its clinical efficacy relative to traditional metals.
Abstract
BACKGROUND: Polyetheretherketone (PEEK) has gained attention as an alternative to metallic implants in orthopaedic applications, including arthroplasty, due to its mechanical properties and biocompatibility. This review evaluates the role of PEEK in arthroplasty and other orthopaedic applications by analysing its biomechanical characteristics, surface modifications, and clinical outcomes METHODS: A comprehensive literature review was conducted using PubMed, PubMed Central (PMC), Scopus, and Embase. Eligible studies included randomised controlled trials, cohort studies, preclinical research, and systematic reviews. RESULTS: PEEK's elastic modulus (3-4 GPa) closely matches that of human cortical bone, potentially reducing stress shielding and enhancing osseointegration. Its inherent radiolucency improves imaging capabilities, while various surface modification techniques, including hydroxyapatite coatings and nanopatterning, have been developed to enhance bone integration. Despite positive preclinical outcomes, clinical studies are predominantly focused on short- to mid-term results, with limited long-term data on implant survivorship and complications. CONCLUSIONS: While PEEK shows promise in orthopaedic applications, further research is necessary to establish its clinical efficacy relative to traditional metals. Addressing the current gaps in long-term studies, regulatory challenges, and manufacturing processes will be crucial for the broader adoption of PEEK implants in orthopaedic surgery. This review highlights the ongoing evolution of PEEK in the field and suggests directions for future research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomimetic Design of Polyetheretherketone (PEEK) Implantable Medical Devices: Research Progress in Structural Biomimicry and Surface Functionalization.Biomimetics (Basel, Switzerland) · 2026
- Current developments in orthopaedic implant technologyJournal of Orthopaedic Surgery and Research · 2025
- Titanium and polyetheretherketone for spinal fusion cages: a comparative narrative review of material behavior, structural design, and clinical translation.Journal of biomaterials science. Polymer edition · 2026
- Analysis of the postoperative mechanical properties of PEEK bone plates in a distal femoral fracture model.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Review on lower limb bone fracture fixation: biomechanics, design, and advancements in additive manufacturing for implantsMaterials & Design · 2025
- Investigating Surface Free Energy, Thermal Properties, and Protein Adsorption of 3D-Printed PAEK Polymers.ACS biomaterials science & engineering · 2026