Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis.
Hilal Algül, Mahzun Yıldız, Eda Gürbüz Dinç, Ferit Dinç, Kaan Orhan, Ayşe Tuba Altuğ
Department of Orthodontics, Faculty of Dentistry, Ankara University, 06560 Ankara, Türkiye. · Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Ankara University, 06560 Ankara, Türkiye.
Key points
From the paper's conclusion- These findings describe the mechanical response to the prescribed forces under the adopted modelling assumptions.
Abstract
The Ertty Gap III appliance has been proposed for the orthopaedic treatment of growing patients with skeletal Class III malocclusion. This study aimed to characterise its modelled mechanical response under a hypothetical force-controlled loading configuration, rather than to reproduce clinical screw activation. A three-dimensional finite element model was constructed by combining craniofacial geometry reconstructed from the CBCT data of a 12-year-old female patient with independently digitised extracted human teeth. A digitised Ertty Gap III appliance was incorporated, and bilateral forces of 1.5 N at the first-molar hooks and an anteriorly directed force of 10 N at the inverted HYRAX® screw body were prescribed. The 10-N force was not calibrated to a 0.25-mm screw opening. Stress, strain, and displacement were evaluated under static and cyclic loading. The mechanical response was concentrated in the premaxillary and anterior maxillary regions, with localised stress and strain around the premaxillary-maxillary suture. Across six anatomical probe locations, von Mises stress ranged from 0.002 to 0.175 MPa, with the highest sampled value recorded in the central incisor alveolar cortex. The highest sampled resultant displacement was approximately 0.013 mm at the anterior premaxillary cortex. Under cyclic loading, the response remained predominantly anterior, with posterior anchorage and dentoalveolar involvement. These findings describe the mechanical response to the prescribed forces under the adopted modelling assumptions. They do not establish the response to a specified HYRAX® opening or demonstrate clinical skeletal correction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Analysis of Dentoalveolar Effects Induced by Various Fixed Functional Appliances: A Three-Dimensional Finite Element Study.Journal of clinical medicine · 2026
- Biomechanical analysis of the behavior of cranial structures under conditions of pathological occlusionKharkiv Dental Journal · 2026
- Initial biomechanical responses during maxillary first molar intrusion across different root-sinus configurations and sinus floor cortical thicknesses: a three-dimensional finite element study.Odontology · 2026
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element AnalysisJournal of Clinical Medicine · 2026
- 3D‑printed modified power ridges for optimized torque control of maxillary incisors in clear aligner treatment: a finite element analysisBMC Oral Health · 2026