Comparative Analysis of Dentoalveolar Effects Induced by Various Fixed Functional Appliances: A Three-Dimensional Finite Element Study.
Eyüp Burak Küçük, Mustafa Onur Şengezer
Department of Orthodontics, Faculty of Dentistry, Hatay Mustafa Kemal University, Hatay 31060, Türkiye.
Key points
From the paper's conclusion- Background/Objectives: The aim of this study was to quantify the dentoalveolar effects of three different orthodontic fixed functional appliances used to correct Class II Division 1 malocclusion using the finite element method.
Abstract
Background/Objectives: The aim of this study was to quantify the dentoalveolar effects of three different orthodontic fixed functional appliances used to correct Class II Division 1 malocclusion using the finite element method. Methods: Three-dimensional models of the mandible, maxilla, and skull were generated from cone-beam computed tomography scans of a patient with Class II malocclusion. The PowerScope2, Forsus Fatigue Resistant Device (FFRD), and Herbst appliances were scanned, digitally reconstructed and positioned on simulated dental arches. Appliance forces were applied to the meshed models to create three different loading conditions. Von Mises and principal stresses in the dentoalveolar structures and instantaneous tooth displacements were calculated using the finite element method. Results: In all simulations, the maxillary teeth moved distally, whereas the mandibular teeth moved mesially, with the latter showing greater overall movement. The Herbst appliance produced the greatest maxillary distalization, while the PowerScope2 caused the greatest mandibular mesialization. Von Mises stress was mainly concentrated on the buccal surfaces, especially on the maxillary first molars, with appliance-specific increases in the premolars/canines and additional palatal stress in the Herbst simulation. Principal stress patterns were similar for the FFRD and PowerScope2, whereas the highest principal stress values were observed in the Herbst simulation. Conclusions: Within the specific boundary conditions of this patient-derived model, the Herbst simulation produced the highest stress values while inducing minimal initial mesial displacement in the mandible, theoretically indicating a potential for reduced mandibular dentoalveolar displacement. In addition, the Herbst appliance demonstrated a more pronounced initial distalizing effect on the maxillary dentition under these simulated conditions. However, due to the inherent reliance on specific static muscle force assumptions, these biomechanical trends should be interpreted with caution and require further dynamic and clinical validation before drawing definitive conclusions regarding clinical advantages.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Response to Hypothetical Force-Controlled Loading with the Ertty Gap III Appliance: A Three-Dimensional Finite Element Analysis.Bioengineering (Basel, Switzerland) · 2026
- The effect of resting tongue pressure, lip-cheek pressure, and interdental force on mandibular arch collapse and mesial molar drift: A preliminary 3D finite element study.PloS one · 2026
- Biomechanical Evaluation of the Temporomandibular Joint Following Multi-Directional Orthognathic Surgery: A Finite Element Analysis.Medical engineering & physics · 2026
- Finite element analysis in dentistry: a comprehensive narrative review of biomechanical principles, clinical applications, and future perspectives.Frontiers in dental medicine · 2026
- Biomechanical evaluation of a customised 3D-printed metal appliance for intrusion of a supra-erupted maxillary second molar: comparative finite element analysis and an illustrative clinical caseBMC Oral Health · 2026
- Finite Element Analysis of Maxillary Molar Intrusion Using Temporary Anchorage Devices: A Comparison of Direct and Indirect Force Loading.Orthodontics & craniofacial research · 2026