Predicting Humphrey 24-2 Visual Field Sensitivity from OCT: A Comparison of Thickness Maps and Printed Summary Parameters.
Min-Sol Kim, Bo-Young Lim, Ho-Gil Jung, Moon Jung Kim
Department of Data Science, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea. · Department of Ophthalmology, National Medical Center, Seoul 04564, Republic of Korea.
Key points
From the paper's conclusion- We compared them by predicting the 52 non-blind-spot sensitivities of the Humphrey 24-2 visual field from 277 paired OCT and visual field examinations in 144 patients.
Abstract
Optical coherence tomography (OCT) measures structural damage in glaucoma objectively and quantitatively. The extent and location of that damage correspond to the severity and position of visual field loss. One OCT session yields two representations of the same scan: thickness maps and the summary parameters the device prints. How well either representation captures that structure-function relationship is unclear, and the two have not been compared within one cohort. We compared them by predicting the 52 non-blind-spot sensitivities of the Humphrey 24-2 visual field from 277 paired OCT and visual field examinations in 144 patients. A convolutional neural network was trained on the thickness maps, and 52 pointwise XGBoost regressors on the summary parameters. The two predictions were combined by late fusion. Fusion reached a pooled root mean square error of 8.069 dB, against 8.660 dB for the parameter branch and 8.540 dB for the image branch. The gain over the parameter branch held across five backbones, three seeds, and a held-out test set. A five-backbone image ensemble also outperformed the parameter branch by 0.852 dB per eye. Fusing the summary parameters into that ensemble, however, did not detectably improve on it. The fusion gain over the parameter branch is, moreover, smaller than the pointwise test-retest variability of standard automated perimetry. In a matched comparison, removing spatial detail within sectors cost the five-backbone ensemble less than 0.2 dB per eye in cross-validation, whereas networks given the same sector values outperformed gradient boosting. The advantage of the map-based pipeline thus lay in the model rather than in spatial detail, at least in cross-validation; the small held-out set confirmed neither result.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multimodal Deep Learning for Humphrey 24-2 Visual Field Prediction: Evaluating the Contribution of Fellow-Eye Information in Glaucoma and Ocular Hypertension.Journal of clinical medicine · 2026
- Real-World External Evaluation of an OCT Image Analysis System (AI-CO) in Relation to Humphrey Visual Field Mean DeviationmedRxiv · 2026
- OCT-Derived Expected Visual Field Function for Quantifying Directional Structure-Function Discordance in Glaucoma and Ocular Hypertension.Diagnostics (Basel, Switzerland) · 2026
- Artificial intelligence and glaucoma structure-function map: a systematic review.BMC ophthalmology · 2026
- Structure–function relationship between central visual field sensitivities and papillomacular bundle thickness measured using a single optical coherence tomography vertical B-scan in patients with glaucomaGraefe's Archive for Clinical and Experimental Ophthalmology · 2026
- Agreement between ganglion cell‐inner plexiform layer metrics from widefield optical coherence tomography and Goldmann II, III, and V in glaucomaOptometry and Vision Science · 2026