Structure-function relationship between central visual field sensitivities and papillomacular bundle thickness measured using a single optical coherence tomography vertical B-scan in patients with glaucoma.
Yasuyuki Oritani, Kenji Suda, Takanori Kameda, Hanako Ohashi Ikeda, Masahiro Miyake, Shogo Numa, Mariko Murata, Kazuya Morino,
Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. · Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. qwm04525@kuhp.kyoto-u.ac.jp.
Key points
From the paper's conclusion- Background The objective of this study was to investigate the correlation between papillomacular bundle (PMB) thickness, measured using a single optical coherence tomography (OCT) vertical B-scan one papillary diameter temporal from the optic disc, and the corresponding visual field (VF) sector composed of 10 − 2 examination points of static automated perimetry (SAP).
Abstract
BACKGROUND: The objective of this study was to investigate the correlation between papillomacular bundle (PMB) thickness, measured using a single optical coherence tomography (OCT) vertical B-scan one papillary diameter temporal from the optic disc, and the corresponding visual field (VF) sector composed of 10 - 2 examination points of static automated perimetry (SAP). The goal was to visualize this relationship as a structure-function map. METHODS: A total of 205 eyes from 125 patients who visited the glaucoma clinic of Kyoto University Hospital between 2015 and 2017 were included. The SAP 10 - 2 examination points were clustered into 3-5 VF sectors using explanatory factor analysis. Retinal nerve fiber layers (RNFL) in the OCT B-scan images were divided into peripapillary vertical RNFL segments (PVRSs) at 5° intervals. The correlation between PVRS thickness and mean sensitivity in each VF sector was examined using linear mixed models. RNFL-VF maps were then constructed, and the PMB range was identified. RESULTS: The PVRSs corresponding to the cecocentral VF sector ranged from - 30° to 25°. The relationship between RFNL thickness of the PVRS sector and mean sensitivity of the corresponding VF sector was nonlinear. CONCLUSIONS: The regional sensitivity of central VF correlated with RNFL thickness measured using a vertical OCT B-scan. Furthermore, the relationship between glaucomatous VF defects and RNFL thinning detected in PVRS shared common characteristics with those of the structure-function relationships previously reported in glaucoma.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Structure-Function Relationships between Tablet-Based Perimetry and Conventional Bowl Perimetry: a Cross-Sectional Study.Ophthalmology. Glaucoma · 2026
- Compatibility of 24-2C central extra test points with OCT and OCTA parameters in early-stage glaucoma.International journal of ophthalmology · 2026
- Visual Cortex Activity and Retinal Changes in Primary Open-Angle Glaucoma: An fMRI and OCTA Study.Medicina (Kaunas, Lithuania) · 2026
- Intraocular Pressure-Induced Strain in the Posterior Pole of Glaucomatous Eyes: Finite Element Analysis Using Eye-Specific Geometry.Journal of clinical medicine · 2026
- Performance of 24-2C Visual Field Grid in Detecting Central Glaucomatous Defects: A Comparative Study with Microperimetry.Journal of glaucoma · 2026
- Predicting Humphrey 24-2 Visual Field Sensitivity from OCT: A Comparison of Thickness Maps and Printed Summary Parameters.Bioengineering (Basel, Switzerland) · 2026