The Impact of Laser Energy Levels on In Situ Fenestrations of Aortic Stent Grafts: An On-Bench Study.
Teodora Ormandzhieva, Florian Elger, Marcello Silvano, Bernd Niemann, Eberhard Grambow
Department of Cardiac, Thoracic and Vascular Surgery, University Medical Center Goettingen, 37075 Göttingen, Germany.
Key points
From the paper's conclusion- This on-bench study compared different laser energy levels in five commercially available endografts to assess fabric damage and evaluate fenestration quality, dimensions, and recoil. (2) Methods: A total of 102 fenestrations were created using a 2.0 mm excimer laser catheter at low (45 mJ/mm2) or high (60 mJ/mm2) energy levels and dilated with a 6 mm plain balloon in five polyester endografts (Ze
Abstract
(1) Background: Laser in situ fenestration (L-ISF) is an endovascular technique used to preserve target vessel patency in urgent or emergency endovascular aortic repair when fenestrated/branched solutions are unavailable or unsuitable, or as a bailout technique for fenestration or branch misalignment. This on-bench study compared different laser energy levels in five commercially available endografts to assess fabric damage and evaluate fenestration quality, dimensions, and recoil. (2) Methods: A total of 102 fenestrations were created using a 2.0 mm excimer laser catheter at low (45 mJ/mm2) or high (60 mJ/mm2) energy levels and dilated with a 6 mm plain balloon in five polyester endografts (Zenith Alpha, RelayPro, Endurant IIs, Valiant Captivia, Hercules). High-magnification microscopy assessed morphology and fabric damage after puncture, after dilation, and after 24 h. Quantitative measurements included diameters, area, and recoil under standardized study conditions. (3) Results: Valiant exhibited clearer puncture margins and no bulging; Hercules showed frequent tearing and more bulging and warp-aligned recoil at high energy. In Endurant IIs, low-energy L-ISF produced larger diameters and area but also greater recoil. RelayPro revealed stronger surface recoil with high energy. (4) Conclusion: Both low- and high-energy L-ISF were feasible across all tested grafts. A low-energy approach may be preferable for Endurant IIs, potentially reducing the risk of bridging stent graft stenosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes from the Real-World Multicenter Laser In-Situ Fenestrated Endovascular Repair (LIFE) Registry for Complex Thoracoabdominal and Pararenovisceral Aortic Pathology.Journal of vascular surgery · 2026
- Impact of BeFlared Bridging Stent Graft on Fluoroscopy and Procedure Time for Fenestrated Endovascular Aneurysm Repair.Annals of vascular surgery · 2026
- A Branch-Specific Combined Fenestration Strategy for Chronic Aortic Dissection With Severe Paravisceral True Lumen Compression.Journal of vascular and interventional radiology : JVIR · 2026
- Stress Waveform Evolution in Rubber‐Modified Epoxy Resin and Dynamic Response in Encapsulation DeviceJournal of Applied Polymer Science · 2026
- Aortic morphology and fenestration-related leak in fenestrated frozen elephant trunk: A cohort study.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Low-Profile Versus Standard-Profile Endograft for Thoracoabdominal and Complex Abdominal Endovascular Aortic Treatment-Multicenter Cohort Study.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026