Aortic morphology and fenestration-related leak in fenestrated frozen elephant trunk: A cohort study.
Koki Ikebata, Kiyoshi Koizumi, Takashi Hashimoto, Hiroaki Kaneyama, Kenichi Hashizume, Hideyuki Shimizu
Department of Cardiovascular Surgery, Japanese Red Cross Ashikaga Hospital, Tochigi, Japan. · Department of Cardiovascular Surgery, Keio University School of Medicine, Tokyo, Japan.
Key points
From the paper's conclusion- Conclusions Fenestration-related leak was associated with larger preoperative aortic diameter and flat TL morphology, most evidently above 36 mm.
Abstract
OBJECTIVES: Objective anatomical criteria for selective fixation of the fenestration after fenestrated frozen elephant trunk (FET) are lacking. We examined the association between preoperative aortic morphology and fenestration-related leak. METHODS: We retrospectively analysed 44 consecutive patients with aortic dissection who underwent fenestrated FET during total arch replacement between 2021 and 2025. True aneurysms were excluded. Preoperative computed tomography (CT) was used to assess aortic short-axis diameter and true lumen (TL) morphology at three levels spanning the left subclavian artery origin. The outcome was fenestration-related leak, defined as persistent perigraft flow on the first postoperative contrast-enhanced CT scan before discharge. Comparisons used exact tests with Firth penalized logistic regression for adjusted associations. RESULTS: Leak occurred in 12 patients (27.3%): 3 of 26 (11.5%) with fixation and 9 of 18 (50.0%) without (P = 0.007). Aortic diameter was larger in patients with leak (34.5 vs 29.9 mm; P = 0.002; area under the curve 0.80, 95% CI 0.63-0.97), and leak incidence rose across diameter strata (12.5%, 57.1%, 80.0%; exact trend P = 0.001). Flat TL morphology was more frequent with leak (P = 0.025); TL position was not associated. Diameter remained associated after penalized adjustment (odds ratio 1.29 per mm; P = 0.001); fixation was independently protective (odds ratio, 0.07; P = 0.002). CONCLUSIONS: Fenestration-related leak was associated with larger preoperative aortic diameter and flat TL morphology, most evidently above 36 mm. Because fixation was chosen intraoperatively and few events occurred, these findings are exploratory and require prospective validation before they can be used to guide selective fixation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Surgical Experience of a Novel Frozen Elephant Trunk Without Distal Stent for Acute Type A Aortic Dissection.Annals of thoracic surgery short reports · 2026
- Perimeter-based oversizing is associated with distal stent graft-induced new entry after frozen elephant trunk repair.Annals of vascular surgery · 2026
- Body Height and Stentgraft Diameter Drive Thrombus Formation After Frozen Elephant Trunk Repair: A Risk-Focused Analysis.The Annals of thoracic surgery · 2026
- Association between stent graft landing zone angle and aneurysm remodelling after total arch replacement with frozen elephant trunk for distal aortic arch aneurysm.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Delayed aortic arch deformity associated with a frozen elephant trunk after total arch replacement.Journal of cardiothoracic surgery · 2026
- Automated Morphological Phenotyping Identifies Anatomic Patterns Associated with Early Type I Endoleak after Endovascular Aortic Repair.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026