Forces and Moments Generated by Thermoforming Aligners and Direct-Printed Aligners: A Systematic Review.
Pritam Mohanty, Saundarya Priyadarshini, Debapreeti Mohanty, Margherita Tumedei, Massimo Del Fabbro, Parameswaran Tirunelveli Mani, Partha Pratim Chaudhary, Balaji Krishnan,
Department of Orthodontics and Dentofacial Orthopaedics, Institute of Dental Sciences, Siksha 'O' Anusandhan University, Bhubaneswar 751029, India. · Department of Paediatric Surgery, All India Institute of Medical Sciences, New Delhi 110029, India.
Key points
From the paper's conclusion- Objectives: This systematic review aims to compare the forces and moments generated by thermoforming aligners and direct-printed aligners in guiding tooth movement in orthodontic patients, evaluating their impact on orthodontic outcomes.
Abstract
Objectives: This systematic review aims to compare the forces and moments generated by thermoforming aligners and direct-printed aligners in guiding tooth movement in orthodontic patients, evaluating their impact on orthodontic outcomes. Methods: A systematic search was conducted in PubMed, Web of Science, and Scopus databases, covering studies on thermoforming and direct-printed aligners from inception to October 2024. Eligible studies included randomized controlled trials, quasi-experimental studies, and observational studies assessing forces and moments generated by these aligners on teeth. In vitro studies pertinent to the topic were also considered. Data extraction focused on study characteristics, aligner details, force and moment measurements, and clinical outcomes. Quality assessment utilized the ROBINS- I for Risk of Bias. The review has been registered on PROSPERO CRD42024620341. Results: A total of nine studies met the inclusion criteria. Findings indicate that thermoforming aligners, while effective in initial force application, exhibit significant force decay over time due to material stress relaxation. In contrast, direct-printed aligners maintain more consistent force levels, potentially resulting in more predictable and sustained tooth movement. Both aligner types vary in their ability to control force direction and magnitude, with direct-printed aligners showing advantages in customization and force retention. Conclusions: The biomechanical properties of thermoforming and direct-printed aligners offer distinct advantages and limitations. Direct-printed aligners may enhance clinical predictability and reduce treatment time through consistent force application, though further research is necessary to validate these benefits in clinical settings. This review underscores the importance of material selection and fabrication method in optimizing orthodontic outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Vitro Comparison of Initial and 7-Day System-Level Resultant Forces in Clear Aligners with Different Layer Structures.Bioengineering (Basel, Switzerland) · 2026
- Direct 3D-Printed Clear Aligners: Materials, Biomechanics, and Clinical Application-A Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- Retention Wear Protocols and Short- to Medium-Term Post-Treatment Stability Following Clear Aligner and Fixed Appliance Therapy: A Systematic ReviewOral · 2026
- CLEAR ALIGNER BIOMECHANICS AND PREDICTABILITY: INHERENT MOVEMENT LIMITATIONS AND THE UNMODELLED ROLE OF MATERIAL FORCE DECAYGlobal journal of research in medicine and dentistry · 2026
- Beyond Nominal Thickness: The Influence of Aligner Thickness on Clear Aligner Biomechanics—A Critical Narrative ReviewBioengineering · 2026
- Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro studyScientific Reports · 2026