Erosion Criterion and Element Size Strongly Affect Simulated Skull Fracture: A Numerical Parametric Study
Hamzah Magsood
Key points
From the paper's conclusion- This numerical parametric study measured how much the element size and the type of erosion criterion change the predicted fracture of one fixed model.
Abstract
Element erosion is widely used to simulate skull fracture in explicit finite element (FE) head models, yet its numerical settings are rarely tested. This numerical parametric study measured how much the element size and the type of erosion criterion change the predicted fracture of one fixed model. A fully solid, skull-shaped bone model built from Human Connectome Project data was used as a numerical test body. It was impacted by a 70 mm, 5 kg sphere at 20 m/s in LS-DYNA. Four runs varied the element size from 3 to 6 mm under a maximum principal stress criterion (SIGP1 = 120 MPa). Three further runs used a maximum principal strain criterion (MXEPS = 0.0086, matched to the SIGP1 limit, and 0.005, from the literature) and a minimum pressure criterion (MNPRES = −40 MPa, also matched). Fracture started at almost the same time for all element sizes (0.35–0.38 ms), but the eroded volume fell from 38.1 cm3 at 3 mm to 0.6 cm3 at 6 mm. At matched failure levels, MXEPS eroded 3.4 times more bone than SIGP1 (30.9 vs. 9.1 cm3), while MNPRES produced no fracture, because the bone under the impactor was strongly compressed. A hollow version of the same skull confirmed the strong mesh effect, and there MNPRES did predict fracture, because the wall could bend. Both settings should therefore be reported and justified in FE skull impact studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of bone-specific material properties on finite element modelling of the skull.Royal Society open science · 2026
- A fractographic and numerical assessment of dental zirconia implant fractures.Journal of the mechanical behavior of biomedical materials · 2026
- The Biomechanical Mechanism of Cranial Implant Exposure Following Decreased Intracranial Pressure: A Finite Element Analysis Study.Biomedicines · 2026
- Mechanical Behavior of A375 Cell Membrane Puncture Based on AFM Experiments and Finite Element Analysis.Microscopy research and technique · 2026
- Biomechanical Effects of Horizontal, Vertical, and Combined Misfits in Full-Arch Implant-Supported Titanium Frameworks: A Three-Dimensional Finite Element Analysis.Journal of functional biomaterials · 2026
- Residual Enamel Stress in a Mandibular First Molar Restored with a Ceromer Onlay Under Vertical and Oblique Loading: A Three-Dimensional Finite Element Analysis.Dentistry journal · 2026