Key points
From the paper's conclusion- Under the forecast deviations tested here, margin protection calibrated from historical capability shortfalls reduces the workload of temporally shiftable tasks left unfinished at their deadlines and increases their on-time workload completion rate relative to conventional rolling optimization without protection.
Abstract
Internet data centers provide scheduling flexibility for AC/DC distribution systems through task deferral and intersite migration. However, conventional rolling scheduling may repeatedly defer tasks to accommodate renewable fluctuations, leaving insufficient execution margin before task deadlines. To address this issue, this paper proposes an intraday rolling optimization method with dynamic task execution margin protection. First, a coordinated model characterizes the temporal and spatial flexibility of computing tasks while jointly considering photovoltaic generation, energy storage, converters, and network constraints. Second, future task-accommodation capability is assessed under current scheduling decisions, and historical capability shortfalls determine the required protection margins. These components are coupled to constrain excessive task deferral during rolling optimization. Finally, case studies are conducted on an AC/DC distribution system with multiple data centers. Simulation results show that coordinated scheduling reduces operating costs and improves photovoltaic utilization compared with fixed task scheduling. Under the forecast deviations tested here, margin protection calibrated from historical capability shortfalls reduces the workload of temporally shiftable tasks left unfinished at their deadlines and increases their on-time workload completion rate relative to conventional rolling optimization without protection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Converter-Aware Coordination of Computing Flexibility in Behind-the-Meter Data CentersarXiv · 2026
- Quantifying the hosting capacity value of workload flexibility for AI data centers: A two-stage electricity-computation co-optimization frameworkarXiv · 2026
- Research on Flexible Response Strategy for Data Center Integrated Energy Systems Considering Dynamic Reliability QuantificationSustainability · 2026
- Job-Level Workload Allocation for Data Centers Under Flexible InterconnectionsarXiv · 2026
- Data center workload flexibility for power system demand response: Evidence from Alibaba tracesInternational Journal of Electrical Power & Energy Systems · 2026
- Virtual Transmission Lines from Data Center Workload Migration: Coordinated Multi-Year Transmission Expansion PlanningarXiv · 2026