Research on Flexible Response Strategy for Data Center Integrated Energy Systems Considering Dynamic Reliability Quantification
Liting Zhang, Sipeng Lai, Fanyue Qian, Xi Xu, Yongwen Yang, Lifei Song, Qifen Li
Key points
From the paper's conclusion- The results show that the proposed strategy can effectively improve energy supply reliability and operational flexibility.
Abstract
With the rapid development of artificial intelligence technologies and the increasing energy demand of data centers, energy systems need to be operated with increasing reliability and flexibility. To address operational risks caused by renewable energy fluctuations and random equipment failures, this study takes a distributed integrated energy system for a data center as the research object and proposes an optimal scheduling strategy that coordinates dynamic reliability and flexibility. First, a dynamic reliability assessment model is established using a sequential Monte Carlo simulation based on a two-state Markov model, and the system’s reliability is quantitatively evaluated using the loss of load probability (LOLP) and expected energy not supplied (EENS). Second, equipment-level and system-level flexibility margin models are developed, and a dynamic reliability baseline constraint is introduced to integrate reliability requirements and regulation capability into a unified optimal scheduling framework. Finally, a simulation case based on the characteristics of a data center in Lingang, Shanghai, is used to evaluate the proposed method under typical seasonal operating conditions. The results show that the proposed strategy can effectively improve energy supply reliability and operational flexibility. Under typical summer conditions, the EENS of the cooling system is reduced by 82.3% compared with the conventional strategy, while the total system operating cost is reduced by 10.93–15.16% under different seasonal conditions. The proposed framework provides an effective approach for the reliability–flexibility-coordinated operation of data center integrated energy systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability-based Sizing of Energy Storage for Large Load IntegrationarXiv · 2026
- Quantifying the hosting capacity value of workload flexibility for AI data centers: A two-stage electricity-computation co-optimization frameworkarXiv · 2026
- Rolling Optimal Scheduling of AC/DC Distribution Systems Considering New Flexible LoadsApplied Sciences · 2026
- Integrating Data Center Flexibility into Power System Operations: A Framework for Temporal RedispatcharXiv · 2026
- Risk-constrained optimization of joint spatio-temporal flexibility of mobile energy storage and data centers under uncertainties in distribution systemsEnergy Reports · 2025
- A Critical Review of Grid Integration Challenges and Flexibility Opportunities for Large-Scale Data CentersarXiv · 2026