Measurement Uncertainty-Bounded Transformer Differential Protection for Islanded Converter-Dominated Power Systems
Yifan Zhao, Yu Liu, Feiyu Lin
Key points
From the paper's conclusion- Transformer differential protection in islanded converter-dominated systems is affected by ratio error, phase error, sampling-time mismatch, harmonic leakage, measurement noise, and current transformer (CT) abnormalities.
Abstract
Transformer differential protection in islanded converter-dominated systems is affected by ratio error, phase error, sampling-time mismatch, harmonic leakage, measurement noise, and current transformer (CT) abnormalities. Reliable discrimination requires the fault contribution to remain distinguishable from their combined effect. This study derives an external-state error upper bound, a fault-component lower bound, and a conditional separability margin. A trajectory-constrained observer then uses CT burden-voltage measurements to constrain shared magnetic parameters and transformer core trajectories. Fixed envelopes missed all 76 internal faults in two equivalent-source datasets, revealing the sensitivity cost of combining independent error bounds. In a separate coupled averaged converter model, the observer was evaluated using split-winding faults, uncapped hysteretic CTs, and finite-bandwidth measurements. Across 24 electromagnetic-transient records and 48 measurement replays, it detected 12/12 internal fault replays with 0/36 non-internal trips and delays of 2.8–17.2 ms. A matched two-slope comparator detected 2/12 and produced 4/36 non-internal trips. Reclosure tests detected eight repeated events; faults lasting 17 ms shortly after reclosure remained undetected and generated late actions. Within the tested model and acquisition conditions, these results indicate that shared trajectory constraints improve sensitivity while identifying the sensitivity of discrimination to post-reclosure timing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A transformer-configuration-aware incremental directional protection scheme for inverter-based resourcesFrontiers in Energy Research · 2026
- Strong-Tracking Observation of Generator Relative Rotor Angle for Transient Control of Cross-Voltage-Level Back-to-Back Converter StationsEnergies · 2026
- Topology-Aware Feasibility Assessment and Coordinated Setting of Transformer Primary and Backup Protection in Islanded Renewable Power SystemsEnergies · 2026
- Transformer-guided Variable Projection for Phasor and Fault-Time Estimation Under DDC OffsetarXiv · 2026
- Protection Channel Competition and Network Feedback in Correlated Converter DisconnectionsElectronics · 2026
- A Catboost-Based Machine Learning Approach for Fault Detection in VSC-Based Multi-Terminal HVDC GridProcesses · 2026