Thermal and Operational Performance of Gravity Loop Heat Pipes with Flat and Finned-Tube Evaporators in a Gas Fireplace Insert
Ľudmila Nová, Patrik Nemec, Jozef Jandačka, Milan Malcho, Andrej Kordoš, Ivan Martinček
Key points
From the paper's conclusion- Loop pressures up to 6.6 bar limited operation.
Abstract
Evaporator designs of passive heat pipes for combustion air preheating in local space heaters have not been compared directly. This study compares two complete evaporator designs of a gravity loop heat pipe in a gas fireplace insert: a flat evaporator with a glass-fibre wick and a copper finned-tube evaporator. Two test series at four settings (4.5–9.6 kW) were compared with a reference without the heat pipe. The heat pipe transferred 953–2040 W to the combustion air (point velocity upper estimate; 523–1202 W from the excess air ratio), preheating it to 50–85 °C. The EN 613 efficiency rose by 1.5–5.7 percentage points at the combustion chamber boundary but changed by only −1.1 to +1.2 for the whole insert, as the evaporator also absorbs firebox radiation and preheating heat largely circulates internally. The finned-tube evaporator started up faster (10–29 vs. 33–42 min), but its series differed by up to 25%. At the highest settings, the flat evaporator lowered the flue gas temperature by 14–15 K but raised the glass temperature by 46–59 K. Loop pressures up to 6.6 bar limited operation. The evaporator design thus mainly affected start-up and firebox and flue gas temperatures; whole-appliance efficiency gains require lower flue gas temperatures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Increasing the Efficiency of Heat Sources Using a Heat PipeMATEC Web of Conferences · 2026
- Thermal performance of a pulsating heat pipe heat exchanger for energy recovery in air conditioning systems in a high-ambient temperature countryJournal of Engineering and Applied Science · 2026
- Thermal Performance Enhancement of a Heat Pipe Heat Exchanger with an Internally Helical-Finned Condenser (HPHIC) using CFD Model for HVAC ApplicationEPJ Web of Conferences · 2026
- Experimental study on space heating performance of PVT-air dual heat source direct expansion heat pump system based on micro heat pipe arraysRenewable Energy · 2026
- Investigating solar air collector performance with different absorber surfaces and Piranha fins through numerical simulationScientific Reports · 2025
- The experimental study on straight heat pipe performance with different working fluids for automobile passive cooling applicationsJournal of Physics: Conference Series · 2026