Thermal performance of a pulsating heat pipe heat exchanger for energy recovery in air conditioning systems in a high-ambient temperature country
Noor Ali Moayad, Wail Sami Sarsam
University of Baghdad
Key points
From the paper's conclusion- At a filling ratio of 50%, the thermal performance of the pulsating heat pipe was consistently superior, attaining the best balance between fluid flow and volume compared to 60% and 70%.
Abstract
Abstract Pulsating heat pipes (PHPs) represent a contemporary and highly efficient thermal technology that utilizes the oscillatory motion of a fluid within capillary tubes to facilitate heat transfer from the evaporator (heat source) to the condenser (heat sink), negating the necessity for moving mechanical components. In this work, a comprehensive experimental study of the thermal performance of a PHP heat exchanger (PHPHE) is conducted, designed to recover waste energy in air conditioning systems and exchange heat between two air streams in a counterflow configuration. The system consists of six rows of pulsating heat pipes (PHPs), each containing six turns, divided into three main sections: evaporator, adiabatic section, and condenser, with lengths of 25, 10, and 25 cm, respectively. The novelty of this study lies in applying a multiple pulsating heat pipe heat exchanger (PHPHE) with pure water, methanol, and acetone as the working fluid for air-conditioning systems, which were utilized at three different fill ratios of 50%, 60%, and 70%. The study examines how using it as a working fluid in PHPHE affects HVAC system performance. Tests were carried out using three air flow velocities (0.5, 0.7, and 0.9 m/s) and three evaporator air inlet temperatures (40 °C, 45 °C, and 50 °C) to investigate their effect on the performance of the PHPHE. Results indicated that raising the inlet air temperature to the evaporator has a positive impact on the heat transfer rate. Results indicated that raising the inlet air temperature to the evaporator has a positive impact on the heat transfer rate. At a filling ratio of 50%, the thermal performance of the pulsating heat pipe was consistently superior, attaining the best balance between fluid flow and volume compared to 60% and 70%. The enhancement ranged between 5.2% and 28.6% for acetone, 5.1% to 26.3% for methanol, and 4.1% to 30.3% for water, confirming that a 50% filling ratio provides the most effective operation. Furthermore, acetone demonstrates superior effectiveness compared to methanol and water, achieving 32% effectiveness at a 50% fill ratio under suitable operating conditions. The overall system effectiveness for the three liquids ranged from a minimum of 15% for water to a maximum of 32% for acetone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The experimental study on straight heat pipe performance with different working fluids for automobile passive cooling applicationsJournal of Physics: Conference Series · 2026
- Experimental Study on Thermal Performance of a Heat Pipe Using Different Refrigerants as a Working FluidSciEn Conference Series Engineering · 2026
- Thermal Performance Enhancement of a Heat Pipe Heat Exchanger with an Internally Helical-Finned Condenser (HPHIC) using CFD Model for HVAC ApplicationEPJ Web of Conferences · 2026
- Impact of bubble nucleation on the functioning of the pulsating heat pipe: numerical simulation studyarXiv · 2026
- Effect of physical properties on heat transfer and flow behavior of flat plate heat pipe with closed meandering channel composed of sintered metal porous sidewallsInternational Journal of Heat and Mass Transfer · 2025
- Optimization of cubic cross‐flow plate heat exchanger based on thermal performance in buildings sustainability for heat‐recovery ventilation using numerical experiments and TAGUCHI methodEnvironmental Progress & Sustainable Energy · 2026