From the paper's conclusion- To address this command–execution frequency mismatch, this paper proposes a decoupled dual closed-loop control architecture for truck-mounted electric water cannons on mobile fire trucks: the fast loop is used for fire-source tracking and rapid localization, while the slow loop is used for water-jet aiming alignment.
Abstract
Fire trucks equipped with truck-mounted electric water cannons are key mobile firefighting assets for urban and industrial fire response. However, due to the inherent mechanical inertia of the cannon body, its low-frequency motion response cannot match high-frequency control commands, making the system prone to oscillations and control instability. To address this command–execution frequency mismatch, this paper proposes a decoupled dual closed-loop control architecture for truck-mounted electric water cannons on mobile fire trucks: the fast loop is used for fire-source tracking and rapid localization, while the slow loop is used for water-jet aiming alignment. In the fast loop, a 2-D quadrant positioning rule drives the pan–tilt unit to achieve rapid fire tracking and accurate centering. In the slow loop, Kalman-filter-based state estimation and delay-aligned prediction generate feedforward aiming commands; these commands are fused with error feedback and further processed through command limiting and trajectory optimization, ultimately producing smooth and executable angle references. The visual perception module ran at 58 FPS, satisfying the real-time requirement of the proposed system. In five repeated extinguishment tests under controlled open-site conditions, the proposed method successfully completed all trials and reduced the mean extinguishment time to 13.55 s, compared with 15.83 s for the incremental-PID baseline and 23.76 s for the coupled proportional baseline, while also showing smoother correction and less redundant oscillation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on Smoke Control Strategies for Tunnel Fires Under Near-Critical Velocity ConditionsFire · 2026
- Smoke Blocking by Water Mist Curtains in Tunnel Fires: A Parametric Study and Momentum-Ratio CriterionFire · 2026
- A Multi-Stage Computer Vision Framework for Real-Time Fire Detection in Low-Light Multi-Camera Environments.Sensors (Basel, Switzerland) · 2026
- Stable tracking of turbulence-disturbed laser communication spots using a time-series state fusion network.Optics express · 2026
- Predict the Swing, Match the Speed: Robotic Pipe Stabbing With Learned Stereo Vision and Residual Reinforcement LearningarXiv · 2026
- A deep learning framework for predicting fire scale and heat release rate via flame pulsation imagesJournal of Thermal Analysis and Calorimetry · 2026