Development and Validation of RP-HPLC Method for Simultaneous Assay and Dissolution Quantitative Analysis of Pitavastatin-Fenofibrate Complex Dual-Layered Tablets
Do-Hyub Kim, Se-Eun Lee, Joo-Eun Kim
Kookmin University
Key points
From the paper's conclusion- Overall, the developed RP-HPLC method provides a validated analytical platform capable of supporting both assay and dissolution testing of pitavastatin–fenofibrate dual-layer tablets.
Abstract
A robust and unified reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous quantitative analysis of pitavastatin calcium and fenofibrate in dual-layer tablet formulations. Although individual analytical methods for each active pharmaceutical ingredient have been reported, a single analytical procedure applicable to both assay and dissolution testing of this fixed-dose combination has not been sufficiently established. In this study, a single RP-HPLC method was optimized to support both quality control purposes, thereby improving analytical efficiency and reducing method-related variability. Chromatographic separation was achieved using a C18 column (4.6 × 150 mm, 5 µm) under isocratic conditions, with a flow rate of 1.1 mL/min, an injection volume of 40 µL, and UV detection at 245 nm. The total run time was 10 min. The method was validated in accordance with ICH guideline Q2(R1) for system suitability, specificity, linearity and range, accuracy, precision (repeatability and intermediate precision), limits of detection and quantitation, and solution stability. Validation was conducted for both assay and dissolution samples using the same chromatographic conditions. The method demonstrated excellent linearity over the validated concentration ranges for both assay and dissolution analyses (r2 ≥ 0.99). Accuracy and precision results satisfied the predefined acceptance criteria for assay (98.0–102.0%) and dissolution-related quantification (95.0–105%), with relative standard deviation values not exceeding 2.0%. The method showed adequate sensitivity, specificity, and solution stability, confirming its suitability for routine analysis. Application of the validated method to finished dual-layer tablets demonstrated reliable assay results and clearly distinguished the rapid dissolution of pitavastatin calcium from the delayed dissolution behavior of fenofibrate. Overall, the developed RP-HPLC method provides a validated analytical platform capable of supporting both assay and dissolution testing of pitavastatin–fenofibrate dual-layer tablets. Beyond routine validation, the proposed analytical framework demonstrates how a single chromatographic condition can support multiple quality attributes, offering an analytically integrated approach for supporting multiple quality attributes in complex combination drug products.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- QbD-driven RP-HPLC method for the simultaneous analysis of dihydropyridines calcium channel blockers in pharmaceuticalsBMC Chemistry · 2025
- A Validated Reversed Phase‐High Performance Liquid Chromatographic Method for Simultaneous Estimation of Bisoprolol Fumarate, Cilnidipine, and Telmisartan With RGB12‐Based Sustainability AssessmentSEPARATION SCIENCE PLUS · 2026
- QbD consideration for developing and validating the dissolution test method for quantitative analysis of tadalafil chewable tablets.Journal of chromatographic science · 2026
- Development and Validation of an RP‐HPLC Method for the Rapid and Sensitive Quantification of Everolimus in Pharmaceutical and Medical Device ApplicationsSEPARATION SCIENCE PLUS · 2026
- AQbD-Driven RP-HPLC Method for Rapid Dissolution Monitoring of Amiodarone Hydrochloride Tablets Without Sample Dilution.Pharmaceuticals (Basel, Switzerland) · 2026
- DEVELOPMENT AND VALIDATION OF STABILITY INDICATING BIOANALYTICAL METHOD FOR SIMULTANEOUS ESTIMATION OF ANTIHYPERTENSIVE DRUGS BY USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)International Journal of Drug Delivery Technology · 2026