Cross-Validation of Low-Cost Potentiometric and Colorimetric Methods for Urinary Urea Quantification: Toward Accessible Monitoring of Protein Metabolism
R. Domínguez, Valerie Yang, Ashley Fu, Edward H. Cheng, Mirna Terrera, Piyush Hota, Ayushi Pradhan, Sandra Miranda,
Phoenix Children's Hospital · BioElectronics (United States)
Key points
From the paper's conclusion- Here, we implement and independently validate two cost-effective methods that resolve urinary urea by pairing the presence and absence of urease: Method 1 is a urease-coupled potentiometric assay using an ammonium ion-selective electrode (ISE method); Method 2 is a microplate Berthelot–salicylate colorimetric assay employing a repurposed consumer-grade aquarium ammonia test kit (API®) (API method)
Abstract
Urinary urea is a key biomarker for tracking protein oxidation and nitrogen balance. A persistent analytical limitation is that conventional total-nitrogen assays do not deconvolute urinary urea from urinary ammonia, and direct measurement still requires capital-intensive clinical analyzers. Here, we implement and independently validate two cost-effective methods that resolve urinary urea by pairing the presence and absence of urease: Method 1 is a urease-coupled potentiometric assay using an ammonium ion-selective electrode (ISE method); Method 2 is a microplate Berthelot–salicylate colorimetric assay employing a repurposed consumer-grade aquarium ammonia test kit (API®) (API method). Each method was validated against the Roche Cobas C311 clinical analyzer (ISE for urinary ammonia and API for urinary urea) in healthy adult volunteers (n = 10 each), and API–ISE were then compared head-to-head for urinary urea. ISE vs. Cobas yielded R2 = 0.967, slope 95% CI [0.867, 1.173], and Bland–Altman bias of −1.02 mM (95% LoA [−7.40, +5.36] mM). API vs. Cobas yielded R2 = 0.973, slope 95% CI [0.790, 1.039], and bias of −1.55 mM (95% LoA [−11.56, +8.46] mM). API–ISE urinary urea comparison confirmed mutual agreement (R2 = 0.9976, slope 95% CI [0.946, 1.024]; bias of +3.47 mM; 95% LoA [−14.60, +21.53] mM), with mean recoveries near 100% (API: 100.7 ± 2.9%; ISE: 100.6 ± 5.4%; 20–350 mM). Both methods agreed with the clinical analyzer, supporting their potential for decentralized, resource-limited testing; clinical and point-of-care validations are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-372 Assessment of Urinary Albumin to Creatinine Ratio Using the Capitainer Dip70® Dried Urine Microsampling Device on Automated Clinical AnalyzersClinical Chemistry · 2026
- The Urine Ammonium-pH Index is a Measure of Kidney Tubular Function.medRxiv : the preprint server for health sciences · 2026
- Making IMPACT (Improving Methodology for Proteinuria and Albuminuria measurement in Clinics and Trials): A Report of the 2025 Proteinuria-Albuminuria Workshop Sponsored by the National Kidney Foundation.American journal of kidney diseases : the official journal of the National Kidney Foundation · 2026
- Urinary creatinine estimation as an important analytical limitation of semi-quantitative albumin-to-creatinine ratio strip testing: a diagnostic accuracy study.Frontiers in medical technology · 2026
- Feasibility of conditional urine culture based on pathological urinalysis: a retrospective diagnostic stewardship study.Antimicrobial stewardship & healthcare epidemiology : ASHE · 2026
- A Comprehensive Analysis of Metrological Traceability Tools for Urine Albumin MeasurementsClinical Chemistry · 2026