Urinary creatinine estimation as an important analytical limitation of semi-quantitative albumin-to-creatinine ratio strip testing: a diagnostic accuracy study.
Piyawan Bunpo, Pharisa Nanthawong, Chananon Chomphusri, Waratchaya Ratchawat, Suwatsin Kittikunnathum, Cheewaporn Tanintheerakul, Rungnapa Peerakam
Division of Clinical Chemistry, Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand. · Clinical Chemistry Laboratory, Diagnostic Service Unit, Faculty of Medicine, Maharaj Nakorn Chiang Mai Hospital, Chiang Mai University, Chiang Mai, Thailand.
Key points
From the paper's conclusion- The findings suggest that semi-quantitative creatinine estimation is the primary analytical determinant of UACR misclassification.
Abstract
BACKGROUND: Albuminuria is a key biomarker for chronic kidney disease and cardiovascular risk. Point-of-care urine albumin-to-creatinine ratio (UACR) testing may improve access to chronic kidney disease screening. However, limited evidence is available regarding the agreement of the individual albumin and creatinine components of semi-quantitative UACR strip tests with quantitative laboratory measurements. METHODS: We evaluated 400 spot urine specimens using the Dirui H13-Cr semi-quantitative UACR strip and compared results with quantitative immunoturbidimetric UACR measurement performed on a Roche Cobas c503 analyzer. Agreement was assessed using Cohen's kappa coefficients, including category-specific agreement according to the KDIGO A1, A2, A3 albuminuria categories, and diagnostic performance was evaluated using sensitivity, specificity, predictive values, likelihood ratios, and diagnostic odds ratio (DOR). RESULTS: Agreement between strip-based and quantitative measurements was substantial for urinary albumin (κ=0.691; 95% CI, 0.632-0.751) but considerably lower for urinary creatinine (κ=0.377; 95% CI, 0.331-0.423). Despite this disparity, UACR classification demonstrated substantial agreement (κ=0.627; 95% CI, 0.541-0.714). The findings suggest that semi-quantitative creatinine estimation is the primary analytical determinant of UACR misclassification. For detection of abnormal albuminuria (UACR ≥30 mg/g), the strip achieved a sensitivity of 83.66% and specificity of 83.22%. The PPV was 89.96% and NPV was 73.91%. Category-specific analysis showed that 131 of 177 A2 specimens (74.0%) were classified as A2 by the strip, whereas 64 of 80 A3 specimens (80.0%) were classified as A2 rather than A3. CONCLUSION: The Dirui H13-Cr strip demonstrated acceptable performance for albuminuria screening. However, semi-quantitative urinary creatinine estimation represented an important analytical limitation affecting UACR classification accuracy. Future development of strip-based UACR technologies should prioritize improved creatinine measurement to enhance diagnostic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Urine dipstick test for assessing albumin-to-creatinine ratio: a pilot study and the potential impact on chronic kidney disease screening.BMC nephrology · 2026
- Diagnostic accuracy of UACR in CKD screening among diabetics: A community study.Bioinformation · 2026
- Conversion of Urine Albumin-Creatinine Ratio to Urine Protein-Creatinine Ratio in Glomerulonephritis: Research Letter.Canadian journal of kidney health and disease · 2026
- A-195 Evaluating Albuminuria and Total Proteinuria in Chronic Kidney Disease: ACR-PCR Agreement and Practice Implications Under KDIGO 2024Clinical Chemistry · 2026
- B-001 Limitations of Urine Dipstick Testing and the Clinical Value of Creatinine-Normalized Quantitative Urinalysis in Urologic and Renal Disease DetectionClinical Chemistry · 2026
- An age-stratified semiquantitative urine ACR triage strategy for quantitative confirmation: a retrospective diagnostic accuracy study with temporal validation.Clinical chemistry and laboratory medicine · 2026