Mechanical Degradation and Fracture Behavior of PBF-LB/M Ti-6Al-4V Induced by Rubber-Glove Contamination
Kerstin Winkler, Andy Schönherr, Frank Schubert, Lothar Kroll
Key points
From the paper's conclusion- This study quantifies the mechanical degradation caused by locally introduced rubber-glove contamination in stress-relieved PBF-LB/M Ti-6Al-4V.
Abstract
This study quantifies the mechanical degradation caused by locally introduced rubber-glove contamination in stress-relieved PBF-LB/M Ti-6Al-4V. Rubber-glove fragments were inserted into defined build layers of standardized tensile specimens and into highly loaded transition regions of a topology-optimized bracket demonstrator. Twelve uncontaminated and twelve contaminated tensile specimens and nine brackets per condition were evaluated. The contaminated tensile specimens exhibited a mean ultimate strength of approx. 860 MPa compared with approx. 1200 MPa for the reference condition, corresponding to a reduction of approx. 28%. Mean elongation at break decreased from approx. 13.4% to 0.6%, representing a reduction of approx. 95%. Fracture preferentially occurred at the contamination insertion region and was associated with planar fracture features and retained spherical powder particles. The results support a predominantly defect-controlled degradation mechanism associated with locally disturbed consolidation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Corrosion-fatigue of L-PBF Ti-6Al-4V lattice struts: role of geometrical imperfections under simulated physiological conditionsInternational Journal of Fatigue · 2026
- The effect of residual stress on the fracture toughness of Ti–6Al–4V produced by laser-based powder bed fusionInternational Journal of Fracture · 2026
- Residual Al2O3 From Grit Blasted Components Operate as Third Body Wear Particles in Total Knee Arthroplasty: An Exploratory Study.Journal of biomedical materials research. Part B, Applied biomaterials · 2026
- Importance of surface defect removal and compressive residual stress introduction in improving fatigue strength of powder bed-fused Ti6Al4V and demonstration of fatigue strength beyond that of hot-rolled Ti6Al4VInternational Journal of Fatigue · 2025
- Influence of controlled interior defect morphology on tensile fracture behavior of binder jetting additively manufactured 17-4PH stainless steelJournal of Materials Research and Technology · 2026
- Effect of Cu Particle Cross-Contamination in AlSi10Mg Powder Feedstock: Tensile and Strain-Hardening Behaviour of Multi-Material Laser Powder Bed Fusion Parts.Materials (Basel, Switzerland) · 2026