科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ International Journal of Fatigue2026-05-16· Lattice (music)

Corrosion-fatigue of L-PBF Ti-6Al-4V lattice struts: role of geometrical imperfections under simulated physiological conditions

Farnoosh Farhad, Simone Murchio, Melika Babaei, Alessandro Albertini, Devid Maniglio, Filippo Berto, M. Benedetti

原始摘要(英文原文)· Original abstract
• Corrosion–fatigue of L-PBF Ti-6Al-4 V lattice struts studied at 60° build orientation. • Fatigue life governed by extreme surface valleys • PBS environment reduces high-cycle fatigue strength by ∼ 25% at 10⁶ cycles. • XCT identifies surface-connected valleys as dominant crack initiation sites. • Environment-assisted crack propagation confirmed by fractography and EDXS. The corrosion-fatigue behaviour of laser powder bed fusion (L-PBF) Ti-6Al-4 V lattice struts was investigated with particular emphasis on the role of manufacturing-induced geometrical imperfections. Thin strut specimens representing strut-based lattice sub-unit elements were built at a 60° orientation and tested under tension–tension loading (R = 0.1) in laboratory air and in phosphate-buffered saline (PBS) at 37 °C. Micro-computed tomography was employed to quantify surface roughness, geometrical deviations, and the interaction between surface valleys and near-surface porosity. Quasi-static tensile tests showed limited scatter in strength and ductility, indicating that monotonic behaviour is governed by global geometry. In contrast, fatigue performance was strongly defect-sensitive. While comparable fatigue strength was observed in air and PBS in the low-cycle regime, exposure to PBS led to a marked reduction in high-cycle fatigue strength, reaching approximately 25% at 10⁶ cycles. Fractographic and EDXS analyses revealed that fatigue cracks initiated at surface-connected valleys in both environments, whereas the physiological environment primarily accelerated crack propagation through corrosion-assisted mechanisms and suppressed crack branching. A micro-CT-based deepest-valley analysis showed good agreement between predicted critical defects and experimental failure locations. The results highlight the dominant role of extreme surface geometrical imperfections and environment-assisted crack growth in the fatigue behaviour of L-PBF Ti-6Al-4 V lattice structures.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Corrosion-fatigue of L-PBF Ti-6Al-4V lattice struts: role of geometrical imperfections under simulated physiological conditions — 科研速览 Science Skim