Plasma Electrolytic Polishing of LPBF Ti-6Al-4V: Surface Integrity, Tensile Fatigue Behaviour of Solid Specimens, and FEA-Guided Stress Analysis of Gyroid Scaffolds
Syed Mesum Raza Naqvi, Xinyuan Tian, Chen Jiao, Jiasen Gu, Syed Zohair Raza Naqvi, Kai Zhou, Siyuan Fan, Hongwei Chen,
Key points
From the paper's conclusion- This study presents an integrated computational–experimental approach to enhance the tensile fatigue life of laser powder bed fusion (LPBF)-fabricated Ti-6Al-4V Gyroid scaffolds for orthopedic implants.
Abstract
This study presents an integrated computational–experimental approach to enhance the tensile fatigue life of laser powder bed fusion (LPBF)-fabricated Ti-6Al-4V Gyroid scaffolds for orthopedic implants. Scaffolds with 60–80% porosity were designed, and finite element analysis (FEA) was employed to analyze localized stress distribution, mechanical behavior, and crack initiation sites under compression, bending, and tensile loading. The FEA results showed that elastic modulus (2.6–8.0 GPa) and compressive yield strength (85.5–251.3 MPa) aligned with human bone requirements. The bending and tensile FEA identified that tensile stress concentrations at exterior node surfaces promoted crack initiation. The LPBF-induced surface roughness further intensified these stresses, accelerating crack nucleation and compromising fatigue life. To address this, plasma electrolytic polishing (PEP) was applied at 240 V for 15, 20, and 25 min on the LPBF Ti-6Al-4V solid tensile specimens and Gyroid scaffolds. To evaluate the effect of PEP on surface integrity and fatigue performance, roughness and tensile fatigue tests were performed on LPBF Ti-6Al-4V solid tensile specimens rather than on porous scaffolds. The PEP for 20 min significantly reduced the average roughness (Ra) from 17.85 ± 1.27 µm (as-built) to 2.84 ± 0.45 µm, with an improvement of 84.10%, while also showing the smooth quality of the Gyroid scaffolds. Consequently, the enhanced surface quality led to a 30.46% increase in the average tensile fatigue cycles to failure (Nf) (σmax = 800 MPa and R = 0.1) of the solid specimens compared to the as-built condition. This improvement indicates the PEP’s effectiveness in enhancing the material fatigue life through surface defect elimination, serving as surface- and material-level supporting evidence for the potential fatigue life improvement of PEP-treated Gyroid scaffolds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Importance of surface defect removal and compressive residual stress introduction in improving fatigue strength of powder bed-fused Ti6Al4V and demonstration of fatigue strength beyond that of hot-rolled Ti6Al4VInternational Journal of Fatigue · 2025
- Corrosion-fatigue of L-PBF Ti-6Al-4V lattice struts: role of geometrical imperfections under simulated physiological conditionsInternational Journal of Fatigue · 2026
- Development of solid reinforced porous femoral components made using electron beam powder bed fusion to meet endurance requirementThe International Journal of Advanced Manufacturing Technology · 2026
- Evaluating the effect of simulated osseointegration on the fatigue behavior of 3D-printed orthopedic implants.Journal of the mechanical behavior of biomedical materials · 2026
- Computed tomography based investigation of critical defects and fatigue failure analysis of very high cycle fatigued Ti-6Al-4V produced by laser powder bed fusionInternational Journal of Fatigue · 2026
- Biomimetic topology design of L-PBF-fabricated Zn-Cu alloy bone scaffolds for balancing mechanical performance and degradation behavior.Biomaterials advances · 2026