A simplified feline phantom and Monte-Carlo simulation can be used to evaluate radiation exposure to veterinary staff during [211At]NaAt treatment.
Tetsuya Sakashita, Kota Onuma, Akito Sugasawa, Ichiro Sasaki, Fuga Sasaki, Hiromitsu Daisaki, Noriko S Ishioka, Nobuhiko Ito,
Department of Quantum-Applied Biosciences, National Institutes for Quantum Science and Technology, Takasaki, Gunma, Japan. · Department of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, Japan.
Key points
From the paper's conclusion- The combined use of a 3D-printed phantom and numerical simulations demonstrated that occupational doses associated with [211At]NaAt treatment were within acceptable levels, and well below the occupational dose limits recommended by the ICRP, supporting the radiological safety of the procedure. The framework is readily applicable to other organs or animal species, thereby supporting the safe and feasible expansion of veterinary nuclear medicine.
Abstract
INTRODUCTION: Targeted alpha therapy using 211At offers high therapeutic efficacy with relatively low occupational radiation exposure. However, in veterinary medicine, staff exposure-particularly during close animal handling-remains insufficiently evaluated. We quantitatively evaluated external occupational radiation exposure to veterinary staff during simulated clinical use of 211At-labeled radiopharmaceuticals, utilizing dose measurements and numerical simulations based on a feline phantom model. MATERIALS AND METHODS: A spherical [211At]NaAt source was placed in the neck of a CT-derived, 3D-printed feline phantom. Ambient dose equivalent rates were measured at two to five distances ranging from the phantom surface to 1 m using a NaI(Tl) scintillation survey meter, with measurement geometry reproducibly controlled by a dedicated 3D-printed phantom. Concurrently, Monte Carlo simulations using the Particle and Heavy Ion Transport Code System (PHITS) modeled 211At photon transport to calculate ambient dose equivalent rates. Simulation results were compared with experimental measurements to validate dosimetric evaluations. RESULTS: Measurements of the ambient dose equivalent rate, Ḣ*(10), using a spherical source and simplified 3D-printed feline phantom showed good agreement with PHITS Monte Carlo simulations at distances within 1 m, except at very low dose rates near the detection limit. Simplified analytical calculations (FORM) consistently overestimated dose rates, particularly at distances within 10 cm, by up to two orders of magnitude, whereas PHITS provided conservative yet realistic estimates. Gamma-ray spectroscopy demonstrated that photons emitted from 211At and its progeny were detectable only at close distances (~10 cm), suggesting that local shielding may be necessary when high activities are administered. In a simplified clinical scenario, the estimated occupational radiation exposure per [211At]NaAt treatment was low, with effective dose, skin equivalent dose, and eye lens equivalent dose values not exceeding 1.11 μSv for any veterinary staff category. CONCLUSION: The combined use of a 3D-printed phantom and numerical simulations demonstrated that occupational doses associated with [211At]NaAt treatment were within acceptable levels, and well below the occupational dose limits recommended by the ICRP, supporting the radiological safety of the procedure. The framework is readily applicable to other organs or animal species, thereby supporting the safe and feasible expansion of veterinary nuclear medicine.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrated spatiotemporal assessment of ambient radiation fields in a nuclear medicine department using OSL and time-resolved Geiger-Müller monitoring.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Clinical translation of targeted alpha therapy: safety, dosimetry, radiation protection, and regulatory considerations.Seminars in nuclear medicine · 2026
- External dose characteristics and radiation-protection metrics after permanent 125I prostate brachytherapy: comparison of conventional and sparse implantation techniques.Radiation protection dosimetry · 2026
- PHITS-based validation of occupational doses during coronary angiography procedures.Radiological physics and technology · 2026
- Monte Carlo simulations of 241 Am α -particle energy distribution, LET distribution, and absorbed dose in a cell layer.Medical physics · 2026
- Monte Carlo microdosimetry of 211at in multi-species thyroid follicle models: AlfaMC versus MCNPX and Geant4.EJNMMI physics · 2026