Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.
Wu Fengqin, Aihelamu Tueraili, Yaqiong Zhao
The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, China.
Key points
From the paper's conclusion- We compared robot-assisted femoral neck system (FNS) fixation plus an additional cannulated compression screw (CCS) in a multiplanar configuration with robot-assisted FNS fixation alone.
Abstract
BACKGROUND: Garden IV femoral neck fractures in young and middle-aged adults are highly unstable and prone to shortening, nonunion, and femoral head necrosis. We compared robot-assisted femoral neck system (FNS) fixation plus an additional cannulated compression screw (CCS) in a multiplanar configuration with robot-assisted FNS fixation alone. METHODS: This retrospective cohort included 172 patients aged 18-60 years who were treated from June 2024 to June 2025; 82 underwent robot-assisted FNS plus CCS fixation and 90 underwent robot-assisted FNS fixation alone. After 1:1 nearest-neighbor propensity score matching without replacement (caliper, 0.2 standard deviations of the logit propensity score), 67 matched pairs were analyzed. Femoral neck shortening at 12 months was defined as the primary analytic endpoint for this report; perioperative, rehabilitation, other radiographic, functional, and complication outcomes were secondary or exploratory. RESULTS: FNS plus CCS required longer operative time (81.67 ± 7.62 vs. 68.67 ± 7.51 min), more fluoroscopic exposures and guidewire adjustments, and a longer total incision (all P < 0.05). It was associated with earlier full weight-bearing (10.74 ± 1.42 vs. 12.47 ± 1.34 weeks), shorter fracture-healing time (4.69 ± 0.52 vs. 5.25 ± 0.43 months), less femoral neck shortening at 12 months (4.46 ± 1.35 vs. 6.08 ± 1.31 mm), and a lower rate of moderate shortening (34.3% vs. 73.1%; all P < 0.001). HHS was higher at 6 and 12 months and VAS was lower at 12 months in the combined group. Any complication occurred in 1.5% versus 10.4% (exact P = 0.070; conditional matched OR, 0.14; exact 95% CI, 0.003-1.11), indicating substantial uncertainty in the safety comparison. CONCLUSIONS: In this propensity score-matched retrospective cohort, robot-assisted FNS plus an additional CCS was associated with less femoral neck shortening, earlier full weight-bearing, shorter fracture-healing time, and better later functional recovery, at the cost of greater operative complexity. Because the safety analysis was underpowered and follow-up was limited to 12 months, these findings should be interpreted cautiously and do not establish long-term safety or femoral head necrosis risk; prospective multicenter studies with longer follow-up are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Femoral Neck System for young and middle-aged adult femoral neck fractures: a trade-off between reduced lateral irritation and increased neck shortening.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Comparison of internal fixation outcomes in young femoral neck fractures: three cannulated compression screws versus the femoral neck system.Frontiers in surgery · 2026
- Targeted Fully-Threaded Screw Augmentation with the Femoral Neck System Reduces Neck Shortening and Posterior Tilt, Leading to Improved Function in Geriatric Garden I-II Femoral Neck Fractures: A Retrospective Comparative Study.Clinics in orthopedic surgery · 2026
- Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures.Frontiers in surgery · 2026
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026
- A retrospective cohort study comparing combined TiRobot navigation and percutaneous minimally invasive FNS fixation versus conventional open reduction FNS for femoral neck fractures.Journal of robotic surgery · 2026