NeglectARm3D: a robotic and virtual reality platform for the three-dimensional assessment of unilateral spatial neglect.
Daniele Somma, Andrea Mannini, Chiara Pedrini, Francesca Cecchi, Egidio Falotico
The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy. · IRCCS Fondazione Don Carlo Gnocchi ETS, Firenze, Italy.
Key points
From the paper's conclusion- These results support the technical feasibility and short-term tolerability of the integrated platform in healthy adults and justify subsequent clinical and psychometric evaluation in stroke survivors with USN.
Abstract
Unilateral Spatial Neglect (USN) significantly impacts functional outcomes post-stroke, yet traditional assessment methods, relying predominantly on two-dimensional (2D) paper-and-pencil tasks, fail to capture the disorder's complexity across three-dimensional (3D) space and, in particular, the role of depth. This paper introduces NeglectARm3D, a platform for the objective and repeatable 3D assessment of USN that integrates the precise kinematic and force measurement of a 7-DOF torque-controlled robot (Franka Research 3) with the immersive 3D stimulus presentation of a commercial head-mounted display (Meta Quest 3). A Cartesian variable impedance controller lets the participant reach freely toward randomized 3D targets (Phase 1, subject in charge), enabling the reconstruction of a volumetric exploration map, and delivers smooth haptic guidance toward neglected targets (Phase 2, robot in charge). As a first step toward clinical deployment, we evaluated the technical behavior, safety, and tolerability of the platform in twelve healthy adults performing thirty reaching trajectories (twenty in Phase 1, ten in Phase 2). The system preserved natural movement velocity ( 0.10 ± 0.02 vs. 0.10 ± 0.01 m/s), achieved large position error in free reaching ( 32.46 ± 14.71 mm) versus precise robot-led convergence ( 3.01 ± 0.43 mm) with reduced interaction force ( 4.96 ± 0.84 vs. 2.59 ± 0.32 N), and maintained physiological movement smoothness (SPARC - 1.87 ± 0.29 vs. - 1.63 ± 0.32 , benchmark - 1.40 ). Usability was high (System Usability Scale 85.60 ± 8.10 ), simulator sickness was low across all subscales, and all participants reported no pain and no perception of danger. These results support the technical feasibility and short-term tolerability of the integrated platform in healthy adults and justify subsequent clinical and psychometric evaluation in stroke survivors with USN.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- HemiBot: design and technical validation of an adaptive Robotic coaching system for Unilateral Spatial Neglect rehabilitation.Frontiers in robotics and AI · 2026
- AS-ULDAR: a ROS 2-based collaborative robotic platform for upper-limb rehabilitation - systems integration and pilot usability evaluation in a clinical environment.Frontiers in robotics and AI · 2026
- Cable-Driven Parallel Robot and Force Guidance Method for 3D Spatial Perception Training of Visually Impaired People.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- A Valid and Reliable Virtual Reality Tool for Assessment of Arm Nonuse Post-StrokemedRxiv · 2026
- Exploratory Patterns of Task Difficulty and Visual Feedback in Virtual Reality-Based Upper-Limb Trajectory Training.JMIR XR and spatial computing · 2026
- Immersive Virtual Reality for Stroke Rehabilitation: Linking Clinical and Digital Measures of Motor Recovery—A Pilot StudyBioengineering · 2026